verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC600 · F.R.L. Combination (filter + regulator + lubricator)

GC60020LF2T AirTAC F.R.L. Combination, NPT3/4, Low-Pressure

The AirTAC GC60020LF2T AirTAC F.R.L. Combination, NPT3/4, Low-Pressure is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT3/4" ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT3/4"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadNPT
$238.79 $246.29Save 3% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC600-20 drain, gauge and thread option on one page All GC600-20 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the GC60020LF2T AirTAC F.R.L. Combination, NPT3/4, Low-Pressure

The GC60020LF2T is an AirTAC GC-series three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one set. This 600-size unit is fitted with 3/4 in NPT ports, a 40 um filter element and differential-pressure drain bowls, a low-pressure type regulator with an embedded square gauge scaled in psi, and a mounting bracket. Because it is the 600 size, the bowls are aluminium alloy. The filter removes water and particulate from the compressed air, the regulator holds a steady downstream pressure, and the lubricator adds oil mist for air-driven tools and cylinders.

This is a genuine AirTAC part. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Rated flow is published as curves rather than a single figure, so we confirm the datasheet figures for your application on request.

GC60020LF2T AirTAC F.R.L. Combination, NPT3/4, Low-Pressure Technical Specifications

ModelGC60020LF2T AirTAC F.R.L. Combination, NPT3/4, Low-Pressure
SeriesGC600 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT3/4" (NPT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialAluminium alloy
Pressure gaugeFitted — square, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC60020LF2T AirTAC F.R.L. Combination, NPT3/4, Low-Pressure

GC600G-series F.R.L. combination, 600 body — sets the port range.
20Port size PT3/4". This body offers 20 = PT3/4", 25 = PT1".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF600-20 filter, GR600-20 regulator and GL600-20 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC600 · PT3/4" · 40 µm
One size downGC400
Two-unit equivalentGFC600-20
Build orderFilter → regulator → lubricator

Where the GC60020LF2T AirTAC F.R.L. Combination, NPT3/4, Low-Pressure Is Used

factory

Bottling line actuator supply

Feeding filtered, regulated and lubricated air to the gripper and pusher cylinders on a bottling line, where the lubricator keeps cylinder seals running smoothly through continuous shifts.

conveyor_belt

Packaging conveyor diverters

Air preparation for the divert and stopper cylinders on a packaging conveyor, with the regulator holding a steady downstream pressure so divert timing stays consistent.

handyman

Maintenance shop air drops

A 3/4 in supply point in a plant maintenance shop feeding impact wrenches, grinders and ratchets, where the oil-mist lubricator extends tool life and the filter keeps rust and scale out.

Is the GC60020LF2T AirTAC F.R.L. Combination, NPT3/4, Low-Pressure the Right Station?

Start with the port and size: this unit is 600 size with 3/4 in NPT ports; smaller 200/300/400 sizes step down to 1/4 in and 3/8 in, so match the size step to the air demand of the machine. The regulator here is the low-pressure type; its exact adjustment range is not published in the material we hold, so confirm it against your working pressure with us before ordering. Drain choice matters too: this configuration uses the differential-pressure drain (the default), while automatic (A) and manual (M) drains are orderable options. The filter element is the standard 40 um grade; specify W for the 5 um grade where finer filtration is needed. The gauge is the embedded square type scaled in psi; external round gauges and MPa or bar scales are alternatives. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.

Because flow is published as curves rather than a single rated number, ask us to confirm sizing against your application before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT3/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowls on the GC600 suit harsher environments than PC bowls. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR600-20 regulator with a GF600-20 filter on that branch.

GC60020LF2T AirTAC F.R.L. Combination, NPT3/4, Low-Pressure FAQ

AirTAC publishes flow for this series as curves, not as a single rated figure, so we do not quote a number. Send us your application details and we will confirm the flow and datasheet figures for the GC600 size on request.

This unit uses the differential-pressure drain, the default for the GC series, which bleeds condensate from the bowls as pressure differential builds. If you prefer, automatic (code A) or manual (code M) drain versions can be ordered instead.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for GC60020LF2T AirTAC F.R.L. Combination, NPT3/4, Low-Pressure

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC60020LF2T and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.