AirTAC GC600 · F.R.L. Combination (filter + regulator + lubricator)

GC60025MF2TK AirTAC F.R.L. Combination, NPT1 (1 in) Port

The AirTAC GC60025MF2TK AirTAC F.R.L. Combination, NPT1 (1 in) Port is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1" ports, a 40 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade40 µm
  • DrainManual drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadNPT
$253.72 $261.22Save 2% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC600-25 drain, gauge and thread option on one page All GC600-25 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the GC60025MF2TK AirTAC F.R.L. Combination, NPT1 (1 in) Port

The AirTAC GC60025MF2TK is a three-piece F.R.L. combination that filters water and particulate from compressed air, regulates downstream pressure, and adds oil-mist lubrication in one assembly. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Regulation is the standard type with an adjust range of 0.05-0.9 MPa (7-130 psi), read on the embedded square gauge fitted here with a psi scale. A reverse/check valve is fitted, and the mounting bracket is included.

This is a genuine AirTAC part. The GC family is available in sizes 200, 300, 400 and 600 with ports from 1/8 in to 1 in, and with choices of drain type, filter grade (40 um standard, 5 um optional), gauge scale (MPa, psi or bar), thread (NPT on this code) and reverse/check valve. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application on request.

GC60025MF2TK AirTAC F.R.L. Combination, NPT1 (1 in) Port Technical Specifications

ModelGC60025MF2TK AirTAC F.R.L. Combination, NPT1 (1 in) Port
SeriesGC600 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1" (NPT thread)
Filtering grade40 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialAluminium alloy
Pressure gaugeFitted — square, psi scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC60025MF2TK AirTAC F.R.L. Combination, NPT1 (1 in) Port

GC600G-series F.R.L. combination, 600 body — sets the port range.
25Port size PT1". This body offers 20 = PT3/4", 25 = PT1".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF600-25 filter, GR600-25 regulator and GL600-25 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC600 · PT1" · 40 µm
One size downGC400
Two-unit equivalentGFC600-25
Build orderFilter → regulator → lubricator

Where the GC60025MF2TK AirTAC F.R.L. Combination, NPT1 (1 in) Port Is Used

factory

Plant air drop for a stamping and fabrication shop

At the header take-off feeding a press hall, this three-unit F.R.L. cleans water and scale out of the main air, holds a set working pressure for the press clamps and air cylinders, and mists oil to the actuated tooling downstream.

build

Automotive assembly line pneumatic tool stations

Mounted at the tool drop on an assembly line, the unit conditions the supply to impact wrenches and nutrunners: the 40 um element stops particulate reaching the tools, the regulator holds consistent torque-setting pressure, and the lubricator feeds the tool motors.

conveyor_belt

Packaging and palletising conveyor actuation

Installed ahead of the valve bank that drives conveyor stops, pushers and palletiser grippers, the combination keeps condensate and dirt out of the valves, pins the circuit pressure for repeatable cylinder stroke speed, and lubricates the actuator seals.

Is the GC60025MF2TK AirTAC F.R.L. Combination, NPT1 (1 in) Port the Right Station?

Start with the port and size step: this unit is size 600 with a NPT1 (1 in) port, the top of the G-series range, so step down to a smaller size only if your line flow allows it - and since flow is published as curves rather than a single rating, ask us to confirm sizing against your application before ordering. The drain here is manual, which means someone bleeds the bowl on a routine; if unattended drainage matters, the automatic or differential-pressure drain codes are the alternatives to specify. Filter grade is the standard 40 um element; the W code gives a 5 um element where finer filtration is needed. The fitted square gauge reads in psi; MPa and bar scales and an external round gauge are the other gauge choices. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.

Quick checklist

  • ✓ Body size for your peak flow (PT1" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowls on the GC600 suit harsher environments than PC bowls. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR600-25 regulator with a GF600-25 filter on that branch.

GC60025MF2TK AirTAC F.R.L. Combination, NPT1 (1 in) Port FAQ

AirTAC publishes flow for the GC series as curves, not as a single rated number, so we do not quote a rated flow, Cv or SCFM figure. Tell us your line pressure and the air demand of the equipment you are feeding, and we will confirm the sizing against the datasheet curves on request before you order.

A manual drain means the filter bowl is bled by hand on a routine, which suits attended cells and lines visited daily. If the unit sits in an unattended location where skipped drains would let condensate carry over, specify the automatic (code A) or differential-pressure (blank) drain version instead - the rest of the GC60025MF2TK specification stays the same.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for GC60025MF2TK AirTAC F.R.L. Combination, NPT1 (1 in) Port

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC60025MF2TK and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.