The AirTAC GFR200C06C1WT AirTAC Filter Regulator 1/8 in NPT, 5 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C06C1WT is a filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in one compact body. This 200-size unit is threaded 1/8 in NPT and is fitted with the fine 5 um filter element (code W), a differential-pressure drain that bleeds collected condensate automatically as flow passes through, a round external pressure gauge scaled in MPa, and a mounting bracket. The standard regulator covers an adjustment range of 0.15-0.9 MPa (20-130 psi), with a maximum inlet pressure of 1.0 MPa (145 psi) and an operating temperature of -5 to 70 C (non-freezing). The bowl on this 200 size is PC (polycarbonate); only the 600 size uses an aluminium alloy bowl.
This is a genuine AirTAC part. The GFR filter-regulator family spans sizes 200, 300, 400 and 600 with a choice of port sizes, PT, G or NPT threads, differential-pressure, automatic or manual drains, 40 um standard or 5 um fine filtration, and square or round gauges in MPa, psi or bar scales. Flow is published as curves rather than a single rating, so ask us and we will confirm the datasheet figures for your application before you order.
| Model | GFR200C06C1WT AirTAC Filter Regulator 1/8 in NPT, 5 um |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Feeds filtered, regulated air to the compact cylinders and grippers of a small pick-and-place module, with the 5 um element protecting the fine pilot valves from particulate carryover.
Supplies clean, pressure-controlled air to the seal-jaw cylinder of a bagging or wrapping machine, where a stable regulated setting keeps seal force repeatable across the shift.
Conditions the air feeding a lab bench fixture or test-rig actuator, with the fine 5 um grade and MPa-scale round gauge suiting instrument-adjacent circuits that need visibly set, clean air.
Start with size and port: 200 is the smallest GFR frame, and this unit takes a 1/8 in NPT port - step up to 300, 400 or 600 if your line needs more flow capacity. This configuration carries the 5 um element (code W) instead of the 40 um standard, which suits point-of-use protection of sensitive valves and instruments; choose 40 um where general upstream protection is enough. Drain choice matters: this unit uses the differential-pressure drain (default), while automatic (A) and manual (M) versions are available. The round gauge here reads in MPa; psi and bar scales and an embedded square gauge are the other catalogue options. Thread is NPT on this unit; PT is the standard thread and G (BSPP) is also an order option. A bracket is included.
One honest note on sizing: AirTAC publishes flow for this family as curves, not as a single rated figure, so we do not quote a flow number here. Send us your application details and we will confirm the datasheet curve and sizing before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR family as performance curves rather than a single rated figure, so we do not quote a flow number. Tell us your application and we will confirm the datasheet curve and check the sizing for you before you order.
The W in the model code selects the optional 5 um fine filtration instead of the 40 um standard element. It is the right choice when protecting sensitive pilot valves, instruments or point-of-use equipment; the 40 um grade remains the standard choice for general upstream air preparation.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.