The AirTAC GFR200C06C1WTK AirTAC Filter Regulator NPT1/8, 5 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR200C06C1WTK is an AirTAC GFR200 filter regulator: one body that removes water and particulate from compressed air and sets downstream pressure. This configuration is the size 200 unit with a 1/8 in NPT port, a fine 5 um filter element (code W), a differential-pressure drain that bleeds collected condensate automatically when flow runs, a round pressure gauge reading in MPa, a built-in reverse/check valve, and the standard regulator with a 0.15-0.9 MPa (20-130 psi) adjustment range. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing). The polycarbonate bowl keeps the condensate level visible at a glance.
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, a choice of 40 um standard or 5 um fine filtration, differential-pressure, automatic or manual drains, square (embedded) or round external gauges with MPa, psi or bar scales, and a reverse/check valve option. Flow is published as curves rather than a single rated figure, so ask us and we will confirm the datasheet figures for your application on request.
| Model | GFR200C06C1WTK AirTAC Filter Regulator NPT1/8, 5 um |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Filtered, regulated air to clamp cylinders on a machining fixture: the 5 um element keeps debris out of the clamp valve, the regulator holds a steady clamping force, and the check valve holds the clamp if supply pressure drops.
Point-of-use conditioning ahead of air-operated lab apparatus or small spray setups, where the fine 5 um grade protects the device and the round MPa gauge gives a clear pressure reading at the bench.
A compact filter-regulator feeding air cylinders on a packaging or labelling conveyor, with the differential-pressure drain clearing condensate during production runs and the gauge letting operators verify set pressure at a glance.
Size and port set the air capacity: the 200 frame with a 1/8 in NPT port suits compact circuits and point-of-use drops; step up to 300, 400 or 600 when the line feeds more cylinders or valves. Drain choice matters: differential-pressure (this unit) drains with flow, automatic drains on a timer-free cycle even at rest, and manual drain suits intermittent duty where an operator can vent the bowl. The 5 um element (code W) is the finer choice over the 40 um standard when downstream equipment needs cleaner air. Gauge scale (MPa, psi or bar) should match the gauges already on the machine, and the check valve holds downstream pressure if upstream supply is interrupted.
Because flow is published as curves and not as a single rated number, we do not quote a rated flow for this unit. Send us your application details and we will confirm sizing against the datasheet curves before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so we do not quote a rated flow, Cv or SCFM number. Tell us your application and required air consumption and we will confirm the sizing from the datasheet curves on request before you order.
The W in the code GFR200C06C1WTK selects the optional 5 um fine filter grade instead of the 40 um standard, for cleaner air to sensitive downstream equipment. The K selects a built-in reverse/check valve, which holds downstream pressure if the upstream supply is interrupted. Both are catalogue options on the GFR200 at this 1/8 in NPT port size.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.