The AirTAC GFR200C06C2WGK AirTAC Filter Regulator G1/8, 5 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C06C2WGK is a filter regulator: it removes water and particulate from compressed air and holds downstream pressure at your setpoint in one compact body. This 200-size unit is ordered with a G1/8 (BSPP) port, a fine 5 um filter element, a differential-pressure drain that bleeds accumulated condensate automatically whenever the pressure drop across the element is high enough, an external round pressure gauge reading in psi, and a built-in reverse (check) valve that lets downstream air escape rather than back-feed through the unit when the supply is shut off. A mounting bracket is included. Maximum inlet pressure is 1.0 MPa (145 psi), the standard regulator covers 0.15-0.9 MPa (20-130 psi), and the working temperature range is -5 to 70 C (non-freezing). The bowl on this size is polycarbonate (PC).
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with ports from 1/8 to 1 inch, a choice of 40 um standard or 5 um fine filtration, differential-pressure, automatic or manual drains, embedded square or optional external round gauges with MPa, psi or bar scales, and G (BSPP) or NPT threads as order options. Flow is published as curves rather than a single rating, so ask us and we will confirm the datasheet figures for your application before you order.
| Model | GFR200C06C2WGK AirTAC Filter Regulator G1/8, 5 um |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Point-of-use conditioning for the air feed to a machining centre's pneumatic tool clamps and chip-clearing jets: the 5 um element keeps fine particulate out of the clamping circuit while the regulator holds a steady setpoint and the check valve prevents back-feed at shutdown.
Conditioning the air to a packaging conveyor's divert gates and bag-seal cylinders, where the fine 5 um grade protects compact valve internals and the psi gauge lets operators verify setpoint at a glance during changeover.
Filtered, regulated air for a lab analyser or instrument cabinet purge, where the 5 um element and stable regulation protect sensitive pneumatics and the check valve stops stored air in the enclosure from pushing back through the unit when the supply is isolated.
Start with the port and size: this unit is the 200 frame with a G1/8 port, the smallest step in the GFR range, so match it to lines and tools with modest air consumption and step up to 300, 400 or 600 if your flow demand is higher. The 5 um element (code W) suits applications that need finer particulate removal than the 40 um standard; note that the finer element loads faster, which the differential-pressure drain helps manage by ejecting condensate as the pressure drop rises. The round psi gauge is the external option - an embedded square gauge with MPa, psi or bar scales is also available in the family. The fitted check valve is worth keeping if downstream cylinders or tanks must not push air back through the regulator at shutdown. G (BSPP) is the thread on this code; PT is the catalogue standard and NPT is available to order. Because flow is published as curves and not a single rated figure, send us your application details and we will confirm sizing against the datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so we do not quote a l/min, m3/h or SCFM number. Tell us your application and we will confirm the relevant datasheet curve and sizing with you before you order.
The W in the code orders the optional 5 um fine filtration instead of the 40 um standard element, and the K orders a built-in reverse (check) valve. Together they suit circuits that need finer particulate removal and must not back-feed air through the regulator at shutdown. The differential-pressure drain, round psi gauge, G1/8 thread and included bracket are also part of this configuration.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.