verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR200 · Filter Regulator (filter + regulator in one body)

GFR200C06C2WK AirTAC Filter Regulator PT1/8, 5 um

The AirTAC GFR200C06C2WK AirTAC Filter Regulator PT1/8, 5 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$53.22 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR200C06C2WK AirTAC Filter Regulator PT1/8, 5 um

The AirTAC GFR200C06C2WK is a filter regulator: in one compact body it removes water and particulate from compressed air and holds the downstream pressure at your set point. This configuration is the 200 size with a PT1/8 port, a 5 um filter element for finer filtration than the 40 um standard grade, and a differential-pressure drain that discharges collected condensate when the pressure differential across the element calls for it. A round gauge reading in psi is fitted so the outlet pressure can be watched and adjusted, a check valve is built in to hold the downstream setting if the supply dips, a mounting bracket is included, and the bowl is polycarbonate (PC).

This is a genuine AirTAC part from the GFR series, which spans sizes 200, 300, 400 and 600 with ports from 1/8 in up to 1 in, plus choices of drain type, filter grade, gauge style and scale, and G (BSPP) or NPT thread options to order. Maximum inlet pressure is 1.0 MPa (145 psi); for this differential-pressure drain configuration the regulator setting range is 0.15-0.9 MPa (20-130 psi); the operating temperature range is -5 to 70 C (non-freezing). Rated flow for the series is published as curves rather than a single figure, so ask us to confirm the datasheet and sizing for your application.

GFR200C06C2WK AirTAC Filter Regulator PT1/8, 5 um Technical Specifications

ModelGFR200C06C2WK AirTAC Filter Regulator PT1/8, 5 um
SeriesGFR200 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR200C06C2WK AirTAC Filter Regulator PT1/8, 5 um

GFR200G-series filter regulator, 200 body — sets the port range.
C0Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR200 · See datasheet · 40 µm
One size upGFR300
Add lubricationGFC200-C0 (two-unit set)

Where the GFR200C06C2WK AirTAC Filter Regulator PT1/8, 5 um Is Used

precision_manufacturing

Robot gripper circuit supply

On a robotic pick-and-place cell, this unit filters the plant air to 5 um and holds a steady regulated pressure to the gripper valves, with the check valve helping hold the setting if the main supply dips mid-cycle.

science

Analytical instrument cabinet

Lab analysers and sample-handling panels need clean, dry, closely set air. The 5 um element protects sensitive pneumatic components inside the instrument, and the psi gauge gives technicians a visible set point at the cabinet.

conveyor_belt

Packaging line print or label head

Small air-operated printing and labelling heads on a conveyor line run off a compact point-of-use supply. This 1/8 in filter regulator sits right at the head, keeping water and fine dirt out of the nozzle circuit.

Is the GFR200C06C2WK AirTAC Filter Regulator PT1/8, 5 um the Right Unit?

The choices in this series are decodable straight from the code. Size 200 with a PT1/8 port suits compact circuits; step up through 300, 400 and 600 as your flow demand outgrows the smaller ports. Drain type: this unit carries the differential-pressure drain (the default); automatic (A) and manual (M) versions exist in the same family. Filter grade: this one has the 5 um element (code W) instead of the 40 um standard - pick 5 um where downstream instruments, transducers or fine control valves need cleaner air. The gauge fitted here is the round type reading in psi; the embedded square gauge is the standard fitting, with MPa or bar scales available. Thread is PT; G (BSPP) and NPT are catalogue options you can order.

One honest note on sizing: AirTAC publishes flow for this series as curves, not as a single rated figure, so we do not quote a number here. Send us your application details and we will confirm the flow curve and the datasheet figures with you before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR200C06C2WK AirTAC Filter Regulator PT1/8, 5 um FAQ

AirTAC publishes flow for the GFR series as curves, not as a single rated figure, so there is no one number we can honestly quote. Tell us your application and we will confirm the flow curve and the full datasheet figures for this exact model on request, so you can size it against your real demand before ordering.

The W in the code GFR200C06C2WK selects the 5 um filter grade, which is the finer optional element; the standard grade in this series is 40 um. Choose 5 um when the downstream equipment - instruments, transducers, fine control valves - needs cleaner air than the standard grade provides. If your circuit only needs general water and particle removal, the 40 um version of the same size is the usual choice.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR200C06C2WK AirTAC Filter Regulator PT1/8, 5 um

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR200C06C2WK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.