The AirTAC GFR200C06C2WT AirTAC Filter Regulator NPT1/8, 5 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C06C2WT is a size-200 filter regulator: it removes water and particulate from compressed air and holds downstream pressure in one compact body. This configuration is fitted with a 1/8 in NPT port, a 5 um filter element (the finer of the two catalogue grades), a differential-pressure drain that bleeds collected condensate automatically as flow passes through, and an external round gauge reading in psi. The standard regulator covers 0.15-0.9 MPa (20-130 psi) of adjustment, maximum inlet pressure is 1.0 MPa (145 psi), and the operating temperature range is -5 to 70 C (non-freezing). At size 200 the bowl is polycarbonate, and a mounting bracket is included.
This is a genuine AirTAC part. The GFR family is offered in sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, a choice of 40 um or 5 um filtration, differential-pressure, automatic or manual drains, embedded square or external round gauges in MPa, psi or bar scales, and PT, G or NPT threads. Flow is published as curves rather than a single rating, so ask us to confirm the datasheet figures for your application before ordering.
| Model | GFR200C06C2WT AirTAC Filter Regulator NPT1/8, 5 um |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Feeding the cylinder and gripper circuit of a compact cartoning or labelling machine, where the 5 um element protects pilot valves from particulate and the regulator holds a steady working pressure.
Supplying a clamp or hold-down cylinder on a machining or assembly fixture, with the round psi gauge letting the operator set and verify clamping pressure at a glance.
Conditioning air for a laboratory or test-bench instrument that needs clean, moisture-reduced air at a fixed pressure, with the finer 5 um grade and automatic differential-pressure drain keeping upkeep minimal.
Start with the port and size step: GFR200 with its 1/8 in port suits the smallest branch lines, while 300, 400 and 600 carry progressively larger ports and higher flow - match the step to the air demand of the circuit rather than oversizing on guesswork. Choose the drain: differential-pressure (as fitted here) needs no attention during flow, automatic drains on a timer-free principle, and manual drains for infrequently visited installations. Choose the element: 40 um is the standard grade for general plant air, 5 um (this unit, code W) for finer protection of valves and instruments. Gauge and scale are selectable - embedded square or external round, in MPa, psi or bar. Thread is PT as standard with G and NPT as order options, and a bracket can be included or omitted.
One honest note on sizing: AirTAC publishes flow for this family as curves, not as a single rated figure, so we do not quote a rated flow number. Send us your application details and we will confirm the sizing against the datasheet curves before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR family as curves rather than a single rated figure, so we do not quote a rated flow number. Tell us your line pressure and the air demand of your equipment and we will confirm the sizing against the datasheet curves on request before you order.
The W in the code GFR200C06C2WT selects the optional 5 um filter grade instead of the 40 um standard. The finer element is chosen where downstream valves, cylinders or instruments need better protection from fine particulate; the standard 40 um grade is available on other GFR200 configurations if your application does not require it.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.