The AirTAC GFR200C06F1TK AirTAC Filter Regulator NPT1/8 is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR200C06F1TK is an AirTAC GFR-series filter regulator: one body that removes water and particulate from compressed air and regulates downstream pressure. This size 200 configuration has a 1/8 in NPT port, a 40 um standard filtration element, and a differential-pressure drain. The built-in standard regulator covers a 0.15-0.9 MPa (20-130 psi) setting range with a maximum inlet pressure of 1.0 MPa (145 psi), and the unit is rated for -5 to 70 C (non-freezing). A square pressure gauge on the MPa scale is fitted, a reverse/check valve is installed, and a mounting bracket is included; the polycarbonate bowl suits general indoor compressed-air service.
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with ports from 1/8 in to 1 in, PT as the standard thread and G or NPT as order options, a choice of 40 um or 5 um (W) filtration, differential-pressure, automatic or manual drains, gauge or no-gauge variants, and an optional reverse/check valve (K). Flow for this series is published as curves rather than a single rating, so ask us to confirm the datasheet figures for your application before ordering.
| Model | GFR200C06F1TK AirTAC Filter Regulator NPT1/8 |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Clean, regulated air to workholding clamps on a machining cell: the 40 um element keeps swarf-laden moisture out of the clamp cylinders while the regulator holds a steady clamping pressure set on the fitted MPa gauge.
Point-of-use supply for conveyor diverter and stopper cylinders in a distribution line, where the check valve holds the set downstream pressure against upstream fluctuation and the differential-pressure drain handles condensate automatically in service.
Air preparation for carton-sealing and bagging machine jaws: filtered, pressure-regulated air at the machine frame, with the included bracket mounting the unit at the point of use and the 1/8 in NPT port suiting compact machine take-offs.
Start with the size and port step: GFR runs from size 200 (1/8 in) up to size 600 (1 in), and the right step depends on the flow your line needs. Because flow is published as curves and not as a single rating, send us your air demand and we will confirm sizing against the datasheet before you order. From there the real choices are: drain type (differential-pressure as the default, automatic with code A, or manual with code M), filter grade (40 um standard, 5 um with W for finer particulate), gauge type and scale (embedded square gauge standard, external round gauge optional, scales MPa, psi or bar), whether a reverse/check valve (K) is fitted, and the thread - PT is the AirTAC standard with G and NPT as catalogue options, as ordered on this NPT unit. A bracket is included unless code J specifies otherwise.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so we do not quote a rated flow number. Tell us your application and required air demand and we will confirm the sizing against the datasheet curves on request before you order.
T means the port is NPT (1/8 in on this size 200 unit); PT is the AirTAC standard thread and G (BSPP) or NPT are the catalogue options you select at order time. K means a reverse/check valve is fitted, which holds the set downstream pressure if the upstream supply drops. This unit also carries the square MPa gauge, the 40 um element, the differential-pressure drain, and the included bracket.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.