The AirTAC GFR200C06F1WT AirTAC Filter Regulator, NPT1/8, 5 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C06F1WT is a size 200 filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single compact body. This configuration has a 1/8 in NPT port, a 5 um filter element for finer filtration than the standard 40 um grade, a differential-pressure drain that bleeds accumulated condensate automatically as pressure drops, and an embedded square pressure gauge with an MPa scale so the setpoint can be read at a glance. The regulator is the standard type with an adjustment range of 0.15-0.9 MPa (20-130 psi), and the unit is rated for a maximum inlet pressure of 1.0 MPa (145 psi) at temperatures from -5 to 70 C (non-freezing).
This is a genuine AirTAC part. The GFR series is available in sizes 200, 300, 400 and 600 with a choice of ports, drain types, filter grades, gauge styles and scales, and G/NPT thread options to order. Flow figures for this series are published as curves rather than a single rating, so ask us to confirm the datasheet figures for your application on request.
| Model | GFR200C06F1WT AirTAC Filter Regulator, NPT1/8, 5 um |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Point-of-use conditioning for a machining centre's pneumatic actuators and tool-clamp circuit: the 5 um element protects fine components from particulate while the regulator holds a steady supply pressure to the spindle-drawbar and clamping lines.
Feeding directional-control valve blocks on a packaging line, where clean, moisture-reduced air at a fixed regulated pressure keeps cylinder stroke timing consistent and the square MPa gauge lets operators verify the setpoint during changeover.
Conditioning the compressed air feed to a lab test rig or pilot-scale process skid, where the 5 um grade and stable regulated pressure support repeatable results and the differential-pressure drain keeps condensate out of sensitive instrumentation.
Size and port set the mechanical fit: this unit is size 200 with a 1/8 in NPT port, the smallest step in the GFR range, so step up to 300/400/600 if your line needs a larger port and more flow. The 5 um element (code W) suits applications that need finer particulate removal than the standard 40 um grade; the differential-pressure drain suits duty where condensate is carried away on pressure drop without manual attention. The embedded square gauge reads in MPa; external round gauges and psi or bar scales are catalogue options. PT is the standard thread and G/NPT are order options, and a mounting bracket is included with this unit.
Flow for the GFR series is published as curves, not a single rated figure, so send us your application details and we will confirm the sizing against the datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so we do not quote one number for this unit. Tell us your line pressure, downstream demand and port arrangement and we will confirm the flow/datasheet figures for your application on request before you order.
The W in the code specifies the 5 um filter element instead of the standard 40 um grade, giving finer particulate removal for sensitive downstream equipment. The drain is the differential-pressure type (the default): condensate collected in the bowl is discharged automatically when the pressure differential across the element rises, so no manual draining is needed in normal duty. A manual-drain or automatic-drain bowl is available as a catalogue option if your duty cycle suits it better.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.