The AirTAC GFR200C06F1WTK AirTAC Filter Regulator NPT1/8 5um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C06F1WTK is a 200-size filter regulator that removes water and particulate from compressed air and sets downstream pressure in one body. This configuration is threaded NPT1/8, carries the 5 um filter element (code W) for finer filtration than the standard 40 um grade, drains condensate by differential pressure, and includes an embedded square pressure gauge with MPa scale. A check valve (code K) is fitted, and the standard regulator covers a setting range of 0.15-0.9 MPa (20-130 psi) with a maximum inlet pressure of 1.0 MPa (145 psi). The polycarbonate bowl suits non-freezing air from -5 to 70 C.
This is a genuine AirTAC part from the GFR filter-regulator line, which spans sizes 200, 300, 400 and 600 with port options from 1/8 to 1 inch, a choice of differential-pressure, automatic or manual drain, 40 um or 5 um filtration, gauge styles and scales, and PT, G or NPT threads. Flow is published as curves rather than a single rating, so ask us to confirm the datasheet figures for your application before ordering.
| Model | GFR200C06F1WTK AirTAC Filter Regulator NPT1/8 5um |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Clean, regulated air at a stable setpoint for solenoid valve islands on a form-fill-seal or cartoning line, with the check valve holding the downstream circuit if the plant air supply drops.
Fine 5 um filtration ahead of precision air cylinders and clamping fixtures on a machine tool, protecting seals and pilot valves from water and fine particulate carryover.
A compact filter-regulator point-of-use station feeding diverters, stoppers and pusher cylinders on a distribution conveyor, with the square MPa gauge giving operators a local pressure readout.
Size 200 with a 1/8 in port is the entry step of the GFR range; step up through 300, 400 and 600 when your required flow outgrows the smaller ports. This unit already carries the finer 5 um element (W) instead of the standard 40 um grade, differential-pressure drain, the square MPa gauge, and a fitted check valve (K) that holds downstream pressure if upstream supply is lost. Thread here is NPT; PT is the standard and G (BSPP) is also a catalogue option. A mounting bracket is included.
Because AirTAC publishes flow only as curves and not as a single rated figure, we do not quote a flow number here. Send us your application details and we will confirm sizing and the full datasheet against the GFR200 curve before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves, not as a single rated number, so we do not state a flow figure here. Ask us for the datasheet and we will confirm the flow curve for the 200-size, 1/8 in port unit against your application before you order.
The W in the code selects the optional 5 um filter grade instead of the 40 um standard, for finer water and particulate removal, and the K selects a fitted reverse (check) valve that keeps downstream pressure from bleeding back if upstream air is lost. Both are factory build options on the GFR200, along with drain type, gauge style and thread.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.