The AirTAC GFR200C06F2 AirTAC Filter Regulator PT1/8 40 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C06F2 is a filter regulator: one body that first removes water and particulate from compressed air, then regulates downstream pressure. This 200-size unit is threaded PT1/8 (1/8 in, PT standard), filters to the standard 40 um grade, and drains condensate by differential pressure, so the bowl empties itself whenever the pressure differential is high enough - no daily manual draining. The standard regulator covers a 0.15-0.9 MPa (20-130 psi) setting range, and the fitted square gauge reads in psi so operators can set and verify line pressure at a glance. A mounting bracket is included.
This is a genuine AirTAC part. The GFR family spans sizes 200 to 600 with port sizes from 1/8 in to 1 in, and each size can be ordered with a different drain type, a 5 um (W) filter element, an alternative gauge scale, or G/NPT threads. Flow figures for this family are published as curves rather than a single rating, so ask us to confirm the datasheet and sizing for your application on request.
| Model | GFR200C06F2 AirTAC Filter Regulator PT1/8 40 um |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
On a small press or clamp station, this unit cleans the shop air to 40 um and holds a steady regulated pressure to the cylinder, with the psi gauge letting setters verify the setting at the machine.
Packaging lines run many small valves and actuators off one drop; this filter regulator at the drop removes water and grit and keeps actuator pressure stable, while the differential-pressure drain keeps the bowl clear without operator rounds.
Robot gripper circuits need clean, dry air at a repeatable pressure so part handling stays consistent; this PT1/8 unit slots into the gripper panel, and the included bracket mounts it beside the valve manifold.
Size up GFR units by the port step first: this 200 size carries PT1/8, and stepping to 300/400/600 moves you to larger ports and more flow capacity. Choose the drain to match maintenance reality: differential-pressure (this unit) drains itself, automatic (A) empties continuously, and manual (M) needs an operator. Filtration is 40 um as standard; order the W code if the application needs 5 um. Gauge scale is selectable (MPa, psi or bar) and this unit ships with the square gauge in psi. Thread is PT as standard, with G (BSPP) and NPT as order options; a bracket is included.
One honest note on sizing: AirTAC publishes flow for this family as curves, not a single rated figure, so please ask us to confirm flow against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR family as curves rather than a single rated figure, so there is no one rated flow number we can quote. Send us your line pressure, downstream demand and acceptable pressure drop, and we will confirm the flow from the datasheet for this exact model before you order.
This model drains condensate by differential pressure: the bowl empties itself whenever the pressure differential is high enough, with no operator action. If your line spends long periods at steady low differential, choose the automatic-drain (A) version; if you prefer a deliberate, supervised drain, choose manual (M).
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.