The AirTAC GFR200C06F2G AirTAC Filter Regulator, G1/8, psi Gauge is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C06F2G is a 200-size filter regulator: it removes water and particulate from compressed air and holds a steady downstream pressure in a single compact body. This configuration has a G1/8 (BSPP) port, a 40 um standard filter element, a differential-pressure drain that bleeds collected condensate automatically as flow passes through, and an embedded square gauge reading in psi so the setting is visible at the wall of the unit. The standard regulator covers a 0.15-0.9 MPa (20-130 psi) setting range, maximum inlet pressure is 1.0 MPa (145 psi), and the operating temperature range is -5 to 70 C (non-freezing). A mounting bracket is included and the polycarbonate bowl suits this size.
This is a genuine AirTAC part. The GFR filter-regulator family is available in sizes 200, 300, 400 and 600 with matching port sizes, a choice of differential-pressure, automatic or manual drain, a 5 um (code W) element where finer filtration is needed, MPa/psi/bar gauge scales, and PT, G or NPT threads. Flow for this series is published as curves rather than a single rated figure, so ask us and we will confirm the datasheet figures for your application on request.
| Model | GFR200C06F2G AirTAC Filter Regulator, G1/8, psi Gauge |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Feeds cleaned, pressure-regulated air to the clamping cylinders and vise actuators on a CNC machining centre, with the square psi gauge letting the setter verify clamp pressure at a glance.
Sits upstream of the sealing-jaw and case-erector cylinders on a packaging conveyor, keeping water and debris out of the valves while holding a stable jaw pressure shift after shift.
Conditions the shop-air drop feeding a lab's pneumatic bench apparatus, filtering incoming compressed air and setting a low, repeatable pressure that the square psi gauge makes easy to check.
Start with the port and size step: GFR200 with its 1/8 in port is the smallest step in the GFR range, so match it to the line size and the air demand of the downstream equipment - if your consumption sits near the top of the 200-size flow curve, step up to GFR300. Choose the drain to suit access: this unit's differential-pressure drain suits lines with steady flow and no easy access for manual draining; pick automatic (code A) where condensate loads are heavier, or manual (code M) where you want positive control. The 40 um element is standard; specify 5 um (code W) only where finer pre-filtration is genuinely required. Gauge scale is selectable (MPa, psi or bar) and this unit ships with the square psi gauge. Thread is G here; PT is the standard thread and G/NPT are catalogue options to order. Flow for the GFR series is published as curves, not a single rating, so send us your application details and we will confirm sizing against the datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as performance curves rather than a single rated figure, so we do not quote one number here. Tell us your line pressure, set pressure and air consumption, and we will confirm the flow figures from the datasheet for this exact model on request.
This model's blank drain code gives the differential-pressure drain: condensate collected in the bowl is discharged automatically by the pressure difference created as air flows through, with no operator action. If your line has intermittent flow or heavy condensate, the automatic drain (code A) or a manual drain (code M) may suit better - both are decodable options in the same series.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.