The AirTAC GFR200C06F2GK AirTAC Filter Regulator G1/8 is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C06F2GK is a 200-size filter regulator that cleans compressed air and holds downstream pressure in one body. It removes water and particulate down to 40 um in the differential-pressure drain bowl, regulates outlet pressure across 0.15-0.9 MPa (20-130 psi), and carries an embedded square gauge scaled in psi so settings can be read at a glance. The fitted reverse/check valve holds downstream pressure if the supply is lost, and a mounting bracket is included. The G1/8 port suits compact circuits and drop lines where a small footprint matters.
This is a genuine AirTAC part from the GFR series, which spans sizes 200, 300, 400 and 600 with port options from 1/8 to 1 inch, a choice of differential-pressure, automatic or manual drain, 40 um or 5 um (W) filtration, gauge scale options, and PT, G or NPT threads. Flow is published as curves rather than a single rating, so ask us to confirm the datasheet figures for your application before ordering.
| Model | GFR200C06F2GK AirTAC Filter Regulator G1/8 |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Mounted ahead of a solenoid valve manifold on a small clamp or ejector circuit, it strips water and chips from the supply and holds a steady regulated pressure so the valves shift consistently shift to shift.
On a bench-top pneumatic press or fixture clamping line, it filters the shop air and sets the working pressure that determines clamping force, with the check valve holding the setting if the main supply drops.
Installed at the drop feeding a control cabinet or panel of pneumatic instruments, it delivers clean, regulated air at the pressure the components were specified for, with the psi gauge visible for routine checks.
Start with the port and size step: 200 size with a G1/8 port is the smallest step in the GFR range, so match it against the flow your circuit needs - we can check the published flow curves against your demand before you order. Choose the drain type for the bowl: differential-pressure (this unit) drains as flow passes, automatic (A) drains continuously, and manual (M) drains only when opened. Filter grade is 40 um standard; specify W for 5 um where finer particulate removal is needed. Gauge scale is selectable (MPa, psi or bar - this unit is psi), thread is PT standard with G and NPT as order options, and the bracket is included on this configuration.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves, not as a single rated figure, so we do not quote a number. Tell us your working pressure and air demand and we will confirm the sizing from the datasheet curves before you order.
K means a reverse/check valve is fitted, so downstream pressure is held if the upstream supply is lost. This unit has no drain letter, which is the differential-pressure drain: the bowl ejects collected water automatically as air flows through, with no drain fitting to set up.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.