The AirTAC GFR200C06F2TK AirTAC Filter Regulator 1/8 in NPT is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR200C06F2TK is an AirTAC GFR-series filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in one compact body. This size 200 unit is threaded 1/8 in NPT, carries the standard 40 um filter element, and drains condensate by differential pressure, so the bowl purges as the pressure differential across the element builds. The fitted square gauge reads in psi, the built-in reverse/check valve holds downstream settings if upstream pressure is lost, and a mounting bracket is included. Maximum inlet pressure is 1.0 MPa (145 psi), the standard regulator adjusts from 0.15 to 0.9 MPa (20-130 psi), and the operating temperature range is -5 to 70 C (non-freezing). The polycarbonate bowl suits this size class.
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with ports from 1/8 in to 1 in, a choice of differential-pressure, automatic or manual drains, a 5 um element option (code W), gauge scale choices, and G or NPT thread options. Flow for this model is published as a curve rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application before ordering.
| Model | GFR200C06F2TK AirTAC Filter Regulator 1/8 in NPT |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Feeding a small CNC fixture or clamping circuit where filtered, pressure-regulated air at a set psi holds workpieces consistently through the shift.
Conditioning the air supply to pick-and-place and sealing cylinders on a compact packaging machine, with the check valve holding the set pressure if the main supply dips.
Providing clean, regulated compressed air to benchtop analytical or test instruments that require a stable, moisture-reduced supply at a fixed pressure.
Start with the port and size step: this unit is size 200 with a 1/8 in NPT thread, the smallest GFR port, so match it to the line size and the air demand of the tools or cylinders it feeds. Choose the drain to suit access: this configuration uses the differential-pressure drain (default); automatic (code A) or manual (code M) drains are available in the family. The standard element is 40 um; specify the W option if you need 5 um filtration. The square gauge here reads in psi; MPa and bar scales are alternatives, and an external round gauge is optional. Thread is NPT on this model; PT is the standard and G (BSPP) is an order option. A bracket is included; the J code omits it.
Because AirTAC publishes flow as performance curves rather than a single rated number, we do not quote a flow figure here. Send us your application details and we will confirm the datasheet and check the sizing against your required flow before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes GFR performance as flow curves rather than a single rated figure, so we do not quote a flow number. Tell us your application and required flow, and we will confirm the datasheet curve and check the sizing for you before you order.
F2 means the embedded square gauge is fitted with a psi scale (MPa and bar scales are the other options). K means a reverse/check valve is built in, which holds the downstream setting if upstream pressure is lost. The unit also carries the standard 40 um element and the differential-pressure drain.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.