The AirTAC GFR200C06F2WG AirTAC Filter Regulator G1/8, 5 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C06F2WG is a GFR200-series filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This configuration is built with a G1/8 (1/8 in) G-thread port, 5 um filtration (the finer of the two catalogue grades), a differential-pressure drain that bleeds condensate automatically whenever the pressure differential is sufficient, and an embedded square gauge scaled in psi. The regulator is the standard type with a 0.15-0.9 MPa (20-130 psi) adjustment range, a reverse/check valve is not fitted, and a mounting bracket is included. The bowl on this size is polycarbonate (PC); only the 600 size uses an aluminium alloy bowl.
This is a genuine AirTAC part. The GFR family spans four sizes (200, 300, 400 and 600) with port sizes from 1/8 in up to 1 in, and is ordered with your choice of drain type, filter grade, gauge style and scale, thread (PT standard; G and NPT as order options), and bracket. Because flow is published as curves rather than a single rated figure, we confirm the datasheet and sizing figures for your application on request.
| Model | GFR200C06F2WG AirTAC Filter Regulator G1/8, 5 um |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Feeds filtered, regulated air to the tool-clamp and actuator circuits of a small CNC machining centre, where the 5 um element protects fine spool valves from particulate carryover.
Supplies a single vacuum-and-gripper station on a carton packaging line, with the psi-scaled square gauge letting operators set and check working pressure at a glance.
Provides clean, precisely set air to a bench-top leak or pressure-decay test rig, where the 5 um grade and fine regulation keep the test circuit free of water and debris.
Start with the size and port: the GFR200 step with its 1/8 in port suits the smallest branch lines, while GFR300/400/600 step up in port and flow capacity - match the step to the air demand of the circuit rather than oversizing on guesswork. This unit carries the 5 um element (code W); the 40 um standard grade is the right choice for general supply protection, while 5 um suits downstream equipment that needs finer particulate removal. Drain choice matters: the differential-pressure drain fitted here needs no operator attention but relies on sufficient line pressure to purge, whereas automatic (code A) and manual (code M) drains are available in the family. The square gauge here is scaled in psi; MPa and bar scales, and an external round gauge, are the other catalogue options. Thread is G here; PT is the standard and NPT is an order option. A bracket is included; code J versions omit it.
One honest note on sizing: AirTAC publishes flow for this family as curves, not as a single rated figure, so please ask us to confirm the flow and datasheet figures against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR family as curves, not as a single rated figure, so we do not quote a flow number here. Tell us your application and we will confirm the flow and datasheet figures for this exact model on request before you order.
In the code GFR200C06F2WG, the W selects the 5 um filtration grade (the 40 um grade is the standard; 5 um is the finer option), and the absence of an A or M drain code selects the differential-pressure drain, which purges condensate automatically when the pressure differential is sufficient. Automatic (A) and manual (M) drain versions are available in the same family.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.