The AirTAC GFR200C06F3WT AirTAC Filter Regulator NPT1/8, 5 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C06F3WT is a GFR-series filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single compact body. This configuration is the size 200 unit with 1/8 in NPT ports, the fine 5 um filter element (code W), a differential-pressure drain that bleeds collected condensate automatically as flow passes through, and an embedded square pressure gauge scaled in bar. The regulator is the standard type with an adjustment range of 0.15-0.9 MPa (20-130 psi), maximum inlet pressure is 1.0 MPa (145 psi), and the operating temperature range is -5 to 70 C (non-freezing). A mounting bracket is included.
This is a genuine AirTAC part. The GFR family is published in sizes 200, 300, 400 and 600 with a choice of port sizes, PT (standard), G or NPT threads, differential-pressure, automatic or manual drains, 40 um standard or 5 um fine filtration, and gauge scale options. Flow figures are published as curves rather than a single rating, so we confirm the datasheet and sizing for your application on request.
| Model | GFR200C06F3WT AirTAC Filter Regulator NPT1/8, 5 um |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Placed ahead of a bank of directional control valves, this unit filters machining condensate and pipe scale down to 5 um and holds a steady regulated pressure so the valves and cylinders on the station cycle consistently through a shift.
On a bench running pneumatic test fixtures or sample-actuation rigs, the 5 um element protects sensitive instruments and small-bore fittings from particles and water, while the bar-scaled gauge lets the operator set and verify test pressure at a glance.
Feeding seal jaws, vacuum generators and reject cylinders on a packaging conveyor, this filter regulator keeps the machine air clean, dry enough for non-freezing operation, and held at the pressure the machine builder specifies.
Start with the size and port: 200 is the smallest GFR frame, and the 1/8 in NPT port suits compact supply drops and low-to-medium air demand - step up to 300/400/600 if your consumption is higher. This unit already carries the fine 5 um element (W); choose 40 um (standard) if you only need coarse water and particle removal and want the lower-cost element. Drain is differential-pressure here, which suits lines with steady flow; pick automatic for intermittent-flow lines or manual where you want operator-controlled bleeding. The fitted square gauge reads in bar; psi and MPa scales are alternatives. Thread is NPT on this unit, while PT is the catalogue standard and G is also orderable. A bracket is included.
Because AirTAC publishes flow as curves rather than a single rated figure, ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so we do not quote a number that could mislead your sizing. Tell us your operating pressure and air demand and we will confirm the flow curve and datasheet figures for this exact model on request before you order.
The W in the code selects the fine 5 um filtration grade instead of the 40 um standard element, which is the right choice when downstream valves, cylinders or instruments need cleaner air. The drain is the differential-pressure type (the default): it bleeds accumulated condensate automatically as air flows through, so no manual draining routine is needed on continuously flowing lines.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.