The AirTAC GFR200C06JC1WT AirTAC Filter Regulator NPT1/8, 5 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C06JC1WT is a size 200 filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in one body. This configuration carries a 1/8 in NPT port, a 5 um filter element (the finer of the two catalogue grades), a differential-pressure drain that bleeds collected condensate automatically as flow passes through, and a round pressure gauge reading in MPa. The standard regulator covers an adjustment range of 0.15-0.9 MPa (20-130 psi), with a maximum inlet pressure of 1.0 MPa (145 psi), and the unit operates from -5 to 70 C in non-freezing conditions. No mounting bracket is fitted on this variant.
This is a genuine AirTAC part. The GFR family is available in sizes 200, 300, 400 and 600 with port sizes from 1/8 in up to 1 in, a choice of 40 um or 5 um filtration, differential-pressure, automatic or manual drains, square or round gauges with MPa, psi or bar scales, and PT, G or NPT threads. Flow is published as curves rather than a single rating, so ask us to confirm the datasheet and sizing figures for your application on request.
| Model | GFR200C06JC1WT AirTAC Filter Regulator NPT1/8, 5 um |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Feeds filtered, pressure-regulated air to the tool-clamp and chuck-actuation circuits of a small CNC machining centre, where the 5 um element protects tight-tolerance valves from particles and the round MPa gauge lets the setter verify setpoint at a glance.
Supplies clean, regulated air to the cylinders that drive diverters, pushers and sealing jaws on a packaging conveyor line, with the differential-pressure drain keeping condensate out of the valves without daily manual blowing-down.
Mounted at the inlet of a compact pneumatic control panel, it filters and regulates the supply branch feeding directional valves and logic elements, with the NPT1/8 port matching the panel's 1/8 in distribution piping.
Start with the port step: size 200 with a 1/8 in NPT port suits compact circuits; step up to sizes 300, 400 or 600 when the circuit demands more flow - we confirm exact sizing against the published curves before you order. This unit already carries the finer 5 um element; the 40 um grade is the standard choice where only coarse protection is needed. The differential-pressure drain needs no operator attention, but automatic or manual drains are available if your service conditions call for them. The fitted round gauge reads in MPa; square gauges and psi or bar scales can be specified instead. PT is the standard thread, with G (BSPP) and NPT as catalogue options - this unit is ordered with NPT. Brackets are optional; this variant ships without one.
Because flow is published as curves rather than a single rated figure, send us your application details and we will confirm the datasheet numbers before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves, not as a single rated figure, so we do not quote a l/min or SCFM number. Send us your application details and we will confirm the datasheet flow curves and check the sizing against your required flow before you order.
The GFR family is offered with a 40 um standard element or a finer 5 um element (code W). This model carries the 5 um grade, which suits circuits with sensitive valves, cylinders or instrumentation that need finer particulate removal than the standard grade provides. If your application only needs coarse protection, the 40 um version of the same size is the usual choice.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.