The AirTAC GFR200C06JC1WTK AirTAC Filter Regulator NPT1/8 is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR200C06JC1WTK is an AirTAC GFR200 filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This configuration has a 1/8 in NPT port, a 5 um filter element (code W), a differential-pressure drain, an external round pressure gauge with MPa scale, and a built-in reverse (check) valve. It is supplied without a mounting bracket. Maximum inlet pressure is 1.0 MPa (145 psi), the regulator adjusts from 0.15 to 0.9 MPa (20-130 psi), and the working temperature range is -5 to 70 C, non-freezing.
This is a genuine AirTAC part. The GFR family is offered in sizes 200, 300, 400 and 600 with ports from 1/8 to 1 in, in PT (standard), G (BSPP) or NPT thread, with differential-pressure, automatic or manual drains, 40 um or 5 um elements, and a choice of gauge and scale. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet figures for your application.
| Model | GFR200C06JC1WTK AirTAC Filter Regulator NPT1/8 |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Filtered and regulated air feeding small pneumatic clamping cylinders on a machining fixture, where the 5 um element protects fine-tolerance components and the gauge lets the setter read the clamp pressure directly.
Supplying divert and stop gates on a packaging conveyor, where the fitted check valve holds the downstream setting during brief upstream pressure dips so gates do not drift mid-sort.
A point-of-use regulator and filter on a lab air bench with 1/8 in NPT drop lines, giving technicians a locally readable MPa gauge and clean, moisture-reduced air to benchtop pneumatic tools.
Size and port set the capacity: this unit is size 200 with a 1/8 in NPT port, the smallest step in the range - step up to GFR300, GFR400 or GFR600 with a larger port when the line needs more air. The 5 um element (code W) suits points where finer particulate removal matters; the 40 um standard element is the usual choice for general supply. The drain here is differential-pressure: it operates on the pressure differential across the element, so there is no manual drain routine. The round MPa gauge is fitted, and the K code adds a reverse/check valve that holds the downstream setting if upstream supply is lost. This variant is NPT; PT (the standard thread) and G (BSPP) versions can be ordered, and a mounting bracket is available as an option. Because flow is published as curves, not a single rating, ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so we do not quote a flow number for this model. Send us your application details - supply pressure and the air demand of the equipment downstream - and we will confirm the relevant flow figures from the datasheet before you order.
The standard GFR element is 40 um, which suits general supply air. The W code on this model specifies the optional 5 um element for points where finer particulate removal matters, such as feeding precision valves, small cylinders or instrumentation. Both grades are catalogue options across the GFR range, so you can match the element to each point of use.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.