The AirTAC GFR200C06JC2G AirTAC Filter Regulator G1/8, 40 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C06JC2G is a 200-size filter regulator: it removes water and particulate from compressed air and holds downstream pressure in a single body. This configuration has a G1/8 (1/8 in) BSPP port, a standard 40 um filter element, a differential-pressure drain, and a round external pressure gauge reading in psi. The standard regulator covers 0.15-0.9 MPa (20-130 psi), maximum inlet pressure is 1.0 MPa (145 psi), and the polycarbonate bowl suits -5 to 70 C (non-freezing) service. No mounting bracket and no reverse/check valve are fitted on this code.
This is a genuine AirTAC part. The GFR family is offered in sizes 200, 300, 400 and 600 with ports from 1/8 to 1 in, manual or automatic drain options, a 5 um element (code W), embedded square or external round gauges with MPa, psi or bar scales, and G or NPT thread variants. Flow is published as curves rather than a single rated figure, so ask us to confirm sizing and datasheet figures for your application.
| Model | GFR200C06JC2G AirTAC Filter Regulator G1/8, 40 um |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Filtered, regulated air at a stable setpoint feeding the solenoid valve manifold that cycles the carton-forming and sealing cylinders, with the 40 um element keeping scale and pipe rust out of the valve seats.
A point-of-use filter regulator at the tool panel, holding steady downstream pressure to the impact driver and air chuck while the differential-pressure drain bleeds condensed water away during the shift.
Regulated supply to the pneumatic gates, stoppers and pushers along a sorting conveyor, where the round psi gauge lets an operator verify setpoints at a glance and the G1/8 port matches compact actuator lines.
Size and port set the air capacity: this is the smallest 200 size with a 1/8 in G thread, so step up to 300, 400 or 600 if your line draws more air. Choose the drain to match the duty - differential-pressure (as here, the no-code default), automatic (A) for unattended draining, or manual (M) for periodic service; the regulation range is 0.15-0.9 MPa (20-130 psi) with differential or automatic drain and 0.05-0.9 MPa (7-130 psi) with manual drain. Pick 40 um (standard) or 5 um (W) filtration, an embedded square or external round gauge in MPa, psi or bar, and PT (standard), G or NPT thread; a mounting bracket is optional. Flow is published as curves, not a single rating, so let us confirm sizing against your application before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so there is no one l/min or SCFM number we can honestly quote. Tell us your application and downstream demand and we will confirm the sizing against the datasheet curves on request before you order.
The C2 code in GFR200C06JC2G specifies the optional external round gauge with a psi scale; the embedded square gauge is the standard fitting and MPa, psi or bar scales can be ordered. If you prefer the square gauge or a different scale, ask us for the matching code.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.