The AirTAC GFR200C06JC2GK AirTAC Filter Regulator G1/8 is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
GFR200C06JC2GK is an AirTAC GFR200 filter regulator: a 200-size unit that removes water and particulate from compressed air and regulates downstream pressure in a single body. This configuration carries a G1/8 (BSPP) port, the standard 40 um filter element, a differential-pressure drain, a fitted round pressure gauge with psi scale, and a reverse/check valve (code K); no mounting bracket is included (code J). The regulator adjusts from 0.15 to 0.9 MPa (20-130 psi), the maximum inlet pressure is 1.0 MPa (145 psi), and the operating temperature range is -5 to 70 C (non-freezing). The bowl on this size is polycarbonate.
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with ports from 1/8 to 1 inch, and catalogue options include automatic or manual drains, a 5 um element (code W), embedded square or external round gauges with MPa, psi or bar scales, and G or NPT threads in place of the PT standard. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application on request.
| Model | GFR200C06JC2GK AirTAC Filter Regulator G1/8 |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Point-of-use air preparation for a solenoid valve manifold on an assembly station: water and scale are stripped out before the valves, and the regulated setting protects the downstream circuit at a stable pressure.
Feeding small clamping cylinders on a fixture or jig: the 1/8 in port suits compact point-of-use installs, the 40 um element keeps debris out of the clamp circuit, and the psi gauge lets the setter read the clamp setting directly.
Conditioning the air supply to small cylinders and actuators on packaging and labeling machinery: the filter-regulator keeps moisture and particles out of the machine circuit while holding the working pressure the machine was set up for.
Start with size: the 200 to 600 step up in port and flow capacity, so match the port (here G1/8) and the published flow curve to your line instead of assuming a single rating. Drain type is a real choice: differential-pressure (this unit, the standard), automatic (A) or manual (M); note that the regulation range is 0.15-0.9 MPa (20-130 psi) with automatic or differential-pressure drains and 0.05-0.9 MPa (7-130 psi) with a manual drain. Filter grade is 40 um standard or 5 um with the W code. Gauge choices are the embedded square gauge or an external round gauge (this code: round, psi scale), with MPa, psi or bar scales. Thread is PT as standard, with G (BSPP) and NPT as order options, and brackets are optional on GFR - this configuration omits one (J). Because flow is published as curves, not a single rating, ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes GFR flow as curves rather than a single rated figure, so we do not quote a rated flow number for this unit. Tell us your application and line conditions and we will confirm the flow and datasheet figures for GFR200C06JC2GK on request before you order.
The differential-pressure drain is the standard for GFR and is what this code carries. Automatic (A) and manual (M) drains are catalogue options on the family. Note the regulation range differs by drain: 0.15-0.9 MPa (20-130 psi) with automatic or differential-pressure drains, and 0.05-0.9 MPa (7-130 psi) with a manual drain. Ask us to quote the alternative configuration.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.