The AirTAC GFR200C06JC3WT AirTAC Filter Regulator NPT1/8, 5 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR200C06JC3WT is an AirTAC GFR200 filter regulator: it removes water and particulate from compressed air and holds downstream pressure in one compact body. This configuration is the size 200 unit with a 1/8 in NPT port, the 5 um filter element (code W), and a differential-pressure drain that bleeds condensate whenever the pressure drop across the element rises, so no routine manual bleeding is needed. The standard regulator covers 0.15-0.9 MPa (20-130 psi), maximum inlet pressure is 1.0 MPa (145 psi), and the operating temperature range is -5 to 70 C (non-freezing). The size 200 bowl is polycarbonate (PC), and the unit is supplied without a mounting bracket, with a round external gauge reading in bar fitted for setpoint checks.
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in up to 1 in, a choice of differential-pressure, automatic or manual drain, 40 um standard or 5 um (W) filtration, embedded square or external round gauges in MPa, psi or bar scales, and PT, G or NPT thread options. Flow for this series is published as curves rather than a single rated figure, so ask us to confirm the datasheet and check sizing for your application before ordering.
| Model | GFR200C06JC3WT AirTAC Filter Regulator NPT1/8, 5 um |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Feeds clean, regulated air to tool changers and clamping actuators on a CNC machining centre. The 5 um element catches fine particulate before it reaches directional valves, and the bar gauge lets setters verify line pressure at the drop.
Suits tight manifolds on lab automation and analytical instrumentation skids, where the 1/8 in NPT port and compact size 200 body fit crowded panels. The differential-pressure drain clears condensate without shutting the line down.
Regulates air to diverters, stop gates and reject pushers on a packaging conveyor. The round bar gauge gives line technicians a quick visual check that setpoints have not drifted during shift changes.
Match the size and port to the air your line actually uses: size 200 with a 1/8 in NPT port suits compact point-of-use drops, while the 300, 400 and 600 frames step up in port and flow capacity - we can check the published flow curves against your demand before you order. Pick the drain to suit maintenance: differential-pressure (fitted here) drains only as the element loads up, automatic drains on its own, and manual needs a routine bleed; note the regulation range differs by drain - 0.15-0.9 MPa (20-130 psi) with differential-pressure or automatic drain, 0.05-0.9 MPa (7-130 psi) with manual. Filter grade is 40 um standard or 5 um with the W code (fitted here); gauge scale is MPa, psi or bar (this unit carries the round bar gauge); thread is PT as standard with G and NPT as order options; and a mounting bracket can be specified if the installation needs one.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so we do not quote one number. Tell us your line demand and we will confirm the flow curve and sizing from the datasheet before you order.
The W code in the model fits the 5 um element, which filters more finely than the 40 um standard to better protect downstream valves, cylinders and instruments. If your application only needs coarse water and particulate removal, the 40 um version of the same size is available - and either way the differential-pressure drain handles condensate automatically.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.