The AirTAC GFR200C06JF1WT AirTAC Filter Regulator NPT1/8 5 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C06JF1WT is a GFR-series filter regulator: it removes water and particulate from compressed air and sets downstream pressure in a single compact body. This 200-size unit is fitted with a 1/8 in NPT port, a 5 um filter element for finer filtration than the standard 40 um grade, and a differential-pressure drain that bleeds accumulated condensate automatically whenever the pressure drop across the element rises. The embedded square gauge reads outlet pressure in MPa, the standard regulator covers a 0.15-0.9 MPa (20-130 psi) setting range, and maximum inlet pressure is 1.0 MPa (145 psi). Operating temperature is -5 to 70 C, non-freezing. The polycarbonate bowl suits the 200 size, and this configuration is supplied without a mounting bracket and without a reverse (check) valve.
This is a genuine AirTAC part from the GFR filter-regulator line, which spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, a choice of differential-pressure, automatic or manual drains, 40 um or 5 um filtration, gauge scale options and PT, G or NPT threads. Flow figures for this series are published as curves rather than a single rating, so ask us to confirm the datasheet and sizing for your application before ordering.
| Model | GFR200C06JF1WT AirTAC Filter Regulator NPT1/8 5 um |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Feeding clean, regulated air to the tool-change clamping circuits and air-blast nozzles on a CNC machining centre, where the 5 um element helps protect sensitive pilot valves from fine particulate.
Conditioning the supply to the cylinder and valve bank manifold on a cartoning or wrapping line, with the square MPa gauge giving the operator a direct read of set pressure at the machine.
Regulating the hold-down pressure on a small pneumatic clamping or press fixture, where the filter stage removes water carried over from the shop air main before it reaches the clamping cylinders.
Size the unit by the flow your line needs at the outlet pressure you run: the GFR range steps through sizes 200, 300, 400 and 600 with matching port sizes, and this code sits at the small end with a 1/8 in NPT port. This configuration already carries the 5 um element (choose 40 um where coarser, standard filtration is enough), a differential-pressure drain (automatic or manual drains are available as alternates), a square gauge scaled in MPa (psi or bar scales and an external round gauge are options), and NPT thread where PT is the standard and G is the other order option. A mounting bracket can be added if the unit will not be screwed directly into a manifold or machine plate.
Because flow for the G-series is published as curves rather than a single rated figure, we do not quote a number here. Send us your application details and we will confirm the datasheet and check the sizing against your required flow and pressure before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so we do not quote a number here. Tell us your line pressure, set pressure and the flow your application needs, and we will confirm the datasheet and check that this 200-size unit with its 1/8 in NPT port is the right step before you order.
The W in the code specifies the 5 um filter grade, one step finer than the 40 um standard element, for applications where finer particulate removal matters. The drain position is blank, which is the differential-pressure type: condensate is discharged automatically when the pressure drop across the element rises, with no operator intervention. Automatic (A) and manual (M) drains are available as alternates if you prefer a different drain behaviour.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.