The AirTAC GFR200C06JF2 AirTAC Filter Regulator PT1/8, psi Gauge is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C06JF2 is a filter regulator: it removes water and particulate from compressed air and holds downstream pressure at your setpoint in one compact body. This 200-size unit is threaded PT1/8 (1/8 in), carries the standard 40 um filter element, and its differential-pressure drain vents collected condensate as the pressure drop across the element builds, so it needs no daily draining. The standard regulator adjusts from 0.15 to 0.9 MPa (20-130 psi), and an embedded square gauge scaled in psi is fitted so you can read and set pressure directly. The polycarbonate bowl suits non-freezing compressed air from -5 to 70 C, with a maximum inlet pressure of 1.0 MPa (145 psi).
This is a genuine AirTAC part. The GFR series spans sizes 200, 300, 400 and 600 with ports from 1/8 to 1 in, and the catalogue options include 5 um (W) filtration, manual or automatic drains, gauge scales in MPa, psi or bar, G or NPT threads, and a reverse/check valve. Flow is published as curves rather than a single rating, so ask us to confirm the datasheet figures for your application before ordering.
| Model | GFR200C06JF2 AirTAC Filter Regulator PT1/8, psi Gauge |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Fixture clamps and swing cylinders need air stripped of water and swarf and held at a steady setpoint so clamp force stays repeatable across a shift. This unit filters to 40 um and regulates in one body at the fixture drop, with the psi gauge giving the setter a direct readout.
Diverter gates, pushers and stop stations on packaging and distribution conveyors run off small-bore cylinders where a compact 1/8 in filter regulator sits neatly at the line drop. The differential-pressure drain keeps condensate off the valves without an operator round.
Sealing jaws, vacuum generators and product-feed actuators on a packaging machine behave consistently only when supplied with clean, regulated air. Feeding the machine's valve manifold from this unit keeps the setpoint stable and the gauge visible for changeover checks.
Step through the GFR sizes (200/300/400/600) to match the port and flow your line needs; this 200-size unit takes PT1/8. Drain choice matters: the differential-pressure drain fitted here works unattended, while manual (M) and automatic (A) drains are order options. The 40 um element is standard; specify W for 5 um when downstream valves or instruments need finer air. Gauge scale (MPa/psi/bar), G or NPT thread, and bracket choice are all decodable options on this series. Because flow is published as curves rather than a single rated figure, send us your application and we will confirm sizing from the datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so there is no one l/min or SCFM number we can honestly quote. Tell us your operating pressure and the demand of the equipment downstream, and we will confirm the sizing against the datasheet curves on request before you order.
The differential-pressure drain is the catalogue default: it vents the bowl when the pressure drop across the 40 um element builds, so it works unattended in normal flow. If your application has low or intermittent flow, or you prefer to control draining yourself, the manual (M) and automatic (A) drain versions are order options in the same series.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.