The AirTAC GFR200C06JF2TK AirTAC Filter Regulator NPT1/8 is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C06JF2TK is a size 200 filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in one body. This configuration has an NPT1/8 (1/8 in) port, a differential-pressure drain on the bowl, standard 40 um filtration, an embedded square gauge scaled in psi, and a built-in reverse/check valve that holds downstream pressure when the upstream supply is lost. It is supplied without a mounting bracket. Maximum inlet pressure is 1.0 MPa (145 psi), the standard regulation range is 0.15-0.9 MPa (20-130 psi), and the working temperature range is -5 to 70 C (non-freezing). The polycarbonate bowl suits this size; only the 600 size uses an aluminium alloy bowl.
This is a genuine AirTAC part. The GFR family is available in sizes 200, 300, 400 and 600 with ports from 1/8 in to 1 in, and with choices of drain type, filter grade (40 um standard, 5 um optional), gauge style and scale, thread (PT standard; G and NPT as order options), bracket and check valve. Flow is published as curves rather than a single rating, so we confirm the datasheet and sizing figures for your application on request.
| Model | GFR200C06JF2TK AirTAC Filter Regulator NPT1/8 |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Feeds filtered, regulated air to the tool-change clamp and air-blast circuit of a CNC machining centre, with the check valve holding the clamp position if shop air drops.
Conditions the air feeding cylinder-actuated divert gates and heat-seal clamps on a carton packaging line, keeping moisture and scale out of the seal cylinders.
Drops line pressure to a set point for one branch of a machine's pneumatic manifold, with the psi gauge giving the operator a local, readable setting.
Start with the port and size step: this unit is size 200 with an NPT1/8 port, and larger sizes (300/400/600) step up in port and flow capacity, so match the step to the air demand of the circuit. Choose the drain type for the bowl: differential-pressure drain (this unit, automatic in normal operation), fully automatic drain, or manual drain for infrequently attended points. Choose the filter grade: 40 um standard for general protection, or the W code for 5 um where finer filtration is needed. Gauge options are the embedded square gauge (this unit, psi scale) or an optional external round gauge, with MPa, psi or bar scales. Thread is PT as standard, with G (BSPP) and NPT as order options; brackets are optional, and this configuration omits one. Flow for this family is published as curves, not a single rated figure, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR family as curves, not as a single rated figure, so we do not quote a rated flow, Cv or SCFM number. Tell us your application and we will confirm the flow and sizing figures from the datasheet on request before you order.
This unit's bowl has a differential-pressure drain: it discharges collected condensate automatically when the pressure differential across the drain rises as the bowl fills, with no operator action in normal running. If the unit sits on a line that is frequently depressurised, an automatic (A) or manual (M) drain version can be ordered instead.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.