The AirTAC GFR200C06JF2WK AirTAC Filter Regulator PT1/8 5 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C06JF2WK is a size 200 filter regulator: water and particulate filtration plus downstream pressure regulation combined in one body. This configuration carries a 5 um filter element (the W grade, one step finer than the 40 um standard), a differential-pressure drain that bleeds collected condensate automatically whenever the pressure differential across the element is high enough, and an embedded square gauge reading in psi so you can set and monitor outlet pressure at a glance. A reverse/check valve is fitted, holding downstream pressure when the upstream supply is interrupted. The PT1/8 (PT thread) port suits compact drop points, the maximum inlet pressure is 1.0 MPa (145 psi), the standard regulator adjusts from 0.15-0.9 MPa (20-130 psi), and the operating temperature range is -5 to 70 C (non-freezing). The bowl on this size is polycarbonate.
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in up to 1 in, and each size can be ordered with manual or automatic drain instead of the differential-pressure default, a 40 um or 5 um element, a psi or bar gauge scale, G (BSPP) or NPT threads, and with or without a mounting bracket. Flow is published by AirTAC as curves rather than a single rated figure, so ask us and we will confirm the datasheet figures for your application on request.
| Model | GFR200C06JF2WK AirTAC Filter Regulator PT1/8 5 um |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Mounted at the fixture drop, the unit strips water and fine swarf-contaminated moisture from the supply, holds a steady clamping pressure read on the psi gauge, and the check valve keeps the clamp from releasing if the main supply drops mid-cycle.
Feeding the divert and pusher cylinders above a conveyor, the 5 um element protects the small control valves from fine particulate, the regulator holds consistent stroke speed, and the differential-pressure drain keeps condensate out of the drop without daily attention.
At a compact analyzer or test-bench panel, the PT1/8 port fits tight instrument drops, the fine 5 um grade and regulated outlet suit sensitive pneumatic components, and the check valve holds the panel pressure stable through supply dips.
Work from the air consumption of the equipment you are feeding: step up through the GFR sizes (200, 300, 400, 600) and their port sizes (1/8 in to 1 in) until the curve for your operating conditions clears the demand with margin. On this unit the 5 um element is the right choice when downstream valves, cylinders or instruments are sensitive to fine particulate; the 40 um standard grade is the economical choice for general shop-air duty. Drain type is a real decision: differential-pressure (as fitted here) drains itself in service, automatic drain suits unattended installations, and manual drain suits points someone already walks past daily. The square gauge here reads psi; MPa and bar scales are available, and an external round gauge is optional. PT is the standard thread on this code, with G (BSPP) and NPT offered as order options, and the J code means no mounting bracket is included - add one if the unit will not be supported by its own piping. Because AirTAC publishes flow as curves and not a single rating, send us your line pressure and air demand and we will confirm sizing against the datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves, not as a single rated number, so there is no one figure we can honestly quote. Send us your inlet pressure, set outlet pressure and the air demand of your equipment, and we will confirm the flow data from the datasheet for this exact 1/8 in, size 200 unit on request.
In the code GFR200C06JF2WK, the W selects the 5 um filter grade instead of the 40 um standard, for applications where finer particulate removal protects downstream valves and cylinders. The K at the end fits a reverse/check valve, which holds downstream pressure if the upstream supply is lost. Both are order-time choices: the 40 um grade and no check valve are the defaults if you prefer them.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.