The AirTAC GFR200C06JF3T AirTAC Filter Regulator NPT1/8 is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C06JF3T is a filter regulator: one body that removes water and particulate from compressed air and holds downstream pressure steady. This size 200 unit has a 1/8 in NPT port, a 40 um filter element, a differential-pressure drain and an embedded square gauge scaled in bar. The regulator is the standard type with a 0.15-0.9 MPa (20-130 psi) adjustment range, maximum inlet pressure is 1.0 MPa (145 psi), no reverse/check valve is fitted, and the unit is supplied without a mounting bracket.
This is a genuine AirTAC part. The GFR family spans sizes 200 to 600 with ports from 1/8 in to 1 in, and the catalogue options include manual or automatic drains, a finer 5 um (W) element, gauge scales in MPa or psi, G (BSPP) or NPT threads in place of the PT standard, and an optional bracket. Rated flow for this series is published as curves rather than a single figure, so ask us to confirm the datasheet and sizing for your application.
| Model | GFR200C06JF3T AirTAC Filter Regulator NPT1/8 |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Point-of-use air preparation for a CNC machining centre: water and swarf-laden shop air is filtered before it reaches tool-changer cylinders and spindle air seals, while the regulator holds a steady working pressure so clamp and tool-change sequences repeat identically shift after shift.
Feeding the pneumatic pushers and flap-fold cylinders on a packaging conveyor line: the 40 um element stops pipe scale and condensed water reaching the cylinder seals, and the bar-scaled gauge lets the line technician set and check the working pressure the actuators were sized for.
Setting the clamping pressure on a pneumatic workholding fixture at a assembly bench: the operator dials the required holding force on the square bar gauge, and the differential-pressure drain bleeds accumulated condensate from the bowl while the fixture is under air.
The real choices on this family: step up from size 200 to 300, 400 or 600 when the line needs a larger port and more flow; pick the drain - differential-pressure (as fitted here), automatic (A) or manual (M); choose the 40 um standard element or the 5 um (W) grade for finer protection of downstream equipment; and set the gauge scale to MPa, psi or bar. Thread is NPT on this unit; PT is the AirTAC standard and G (BSPP) is also available to order. A mounting bracket is optional - this configuration is supplied without one.
Flow for the GFR series is published as curves, not a single rated number, so send us your flow and pressure requirements and we will confirm the correct size from the datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves, not as a single rated figure, so there is no one l/min or SCFM number we can honestly quote. Tell us your required flow and working pressure and we will confirm the sizing for this exact unit from the datasheet on request.
Yes. PT is the AirTAC standard thread for the GFR series, and G (BSPP) and NPT are catalogue options selected with the thread suffix on the model code. The thread choice is a specification you order, so pick the one that matches your piping before confirming the purchase.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.