The AirTAC GFR200C06JF3TK AirTAC Filter Regulator NPT1/8 is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR200C06JF3TK is an AirTAC GFR-series filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This size 200 unit has a 1/8 in NPT port, a 40 um standard filter element, differential-pressure draining of the polycarbonate bowl, an embedded square gauge with a bar scale, and a built-in reverse (check) valve that holds downstream pressure if the upstream supply dips. Maximum inlet pressure is 1.0 MPa (145 psi), the regulation range is 0.15-0.9 MPa (20-130 psi), and the working temperature range is -5 to 70 C (non-freezing). No mounting bracket is included.
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with ports from 1/8 to 1 in, and options including 5 um filtration (code W), automatic or manual drains, gauge scales in MPa, psi or bar, an external round gauge, a mounting bracket, and PT, G or NPT threads. Flow for this series is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application.
| Model | GFR200C06JF3TK AirTAC Filter Regulator NPT1/8 |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Feeding clean, regulated air to the tool-clamp and fixture-actuation circuits of a CNC machining centre, with the built-in check valve holding clamp pressure if the shop supply dips.
Supplying regulated air to the cylinders and grippers on a carton-sealing machine, where the 40 um element protects valve seals from pipe scale and condensed water.
Mounting ahead of a bank of quarter-turn actuator solenoid valves on a water-treatment skid, holding a steady set pressure between 0.15 and 0.9 MPa despite compressor swings.
Size and port: GFR200 is the smallest GFR frame with a 1/8 in port; step up to 300, 400 or 600 (1/4 to 1 in) when the line needs more flow, matching the port step to pipe size and air demand. Drain: this unit uses differential-pressure draining, which expels collected condensate automatically as the pressure differential rises; manual (M) and fully automatic (A) drains are order options. Filtration: 40 um standard here, 5 um with code W where finer protection is needed. Gauge: embedded square gauge with a bar scale on this code; MPa or psi scales and an external round gauge are available. Thread: NPT as ordered, with PT as the standard and G (BSPP) also offered. No mounting bracket is fitted on this code. Flow for the series is published as curves, not a single rating, so send us your pressure and air-demand figures and we will confirm sizing against the datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so we do not quote a number here. Tell us your working pressure and air demand and we will confirm the flow from the datasheet and check the sizing against your application before you order.
K fits a reverse (check) valve in the unit. If upstream pressure falls, the valve holds the regulated downstream pressure instead of letting it bleed back through the filter regulator, which is useful on clamp and hold circuits. This unit also carries an embedded square gauge with a bar scale; MPa and psi scales are order options.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.