The AirTAC GFR200C06JNWTK AirTAC Filter Regulator NPT1/8, 5 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR200C06JNWTK is an AirTAC GFR-series filter regulator: water and particulate filtration plus downstream pressure regulation combined in one body. This 200-size unit is ordered with an NPT1/8 (1/8 in) port, a 5 um filter element (the finer of the two catalogue grades, versus the 40 um standard), a differential-pressure drain that bleeds collected condensate automatically as flow passes through, and a built-in reverse/check valve that holds the downstream setting if upstream supply is interrupted. No gauge is fitted with this code, and no mounting bracket is included. Maximum inlet pressure is 1.0 MPa (145 psi), the standard regulation range with this drain type is 0.15-0.9 MPa (20-130 psi), and the operating temperature range is -5 to 70 C (non-freezing). The bowl on this 200 size is polycarbonate.
This is a genuine AirTAC part. The GFR family is published in 200, 300, 400 and 600 sizes covering 1/8 in to 1 in ports, with manual, automatic or differential-pressure drains, 40 um or 5 um elements, gauge options, and PT, G or NPT threads as order choices. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application before ordering.
| Model | GFR200C06JNWTK AirTAC Filter Regulator NPT1/8, 5 um |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Feeding a compact clamping cylinder on an assembly fixture: the 5 um element protects the valve and cylinder from particulate, the regulator holds a steady clamp pressure, and the check valve keeps the setting if plant air dips.
Supplying individual actuator circuits on a cartoning or wrapping machine, where the 1/8 in port matches compact control valves and the differential-pressure drain keeps condensate off the downstream components without operator attention.
Regulating clean, dry air to a bench-top test rig or sample-handling gripper, where the finer 5 um grade and stable regulated output matter and the check valve preserves the set pressure during supply interruptions.
Size and port set the flow capacity: this unit is the smallest GFR size (200) with a 1/8 in NPT port, so step up to 300/400/600 if your line needs more air. The 5 um element here suits points where finer particulate matters; the 40 um grade is the standard choice for general supply. The differential-pressure drain needs no operator attention, while automatic and manual drains are the other catalogue options. A gauge can be added on other codes (square embedded or external round, with MPa, psi or bar scale), and brackets are available - this code carries neither. PT is the standard thread; G and NPT are order options, and this unit is specified NPT.
One honest note on sizing: AirTAC publishes flow for this family as curves, not a single rated number, so we cannot quote a rated flow figure. Send us your application conditions and we will confirm the datasheet and correct size before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR family as curves, not as a single rated figure, so we do not quote a rated flow number. We will confirm the datasheet flow curve for this 200-size, 1/8 in NPT unit against your application conditions on request - just ask before ordering.
The N in the code means no gauge is fitted. Gauges are a catalogue option on GFR units - an embedded square gauge or an external round gauge, with MPa, psi or bar scale - so choose a code with a gauge position if you want a fitted indicator, or add a gauge elsewhere in your circuit.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.