The AirTAC GFR200C06LC1T AirTAC Filter Regulator NPT1/8 Low-Pressure is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C06LC1T is a GFR-series filter regulator: it removes water and particulate from compressed air and holds downstream pressure in a single body. This size 200 unit comes with a 1/8 in NPT port (T thread), the standard 40 um filter element, a differential-pressure drain, and a round pressure gauge with MPa scale. The L in the code marks the low-pressure regulator type, and a mounting bracket is included.
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with ports from 1/8 in to 1 in, and options including automatic or manual drains, a 5 um (W) filter element, square or round gauges with MPa, psi or bar scales, and G (BSPP) or NPT threads in place of the PT standard. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing. Flow is published as curves rather than a single rating, so ask us to confirm sizing and datasheet figures for your application.
| Model | GFR200C06LC1T AirTAC Filter Regulator NPT1/8 Low-Pressure |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Filter and hold a steady regulated pressure to the clamp cylinders on a CNC fixture, keeping part seating consistent through every cycle.
Clean, regulated air at reduced pressure for bench-top test rigs and laboratory actuators, with the MPa gauge giving a direct readout at the bench.
Conditioning the air feeding diverters, pushers and seal cylinders on a packaging conveyor, where the low-pressure regulator type is specified for circuits run at reduced pressure.
Choose the GFR size by the port step your line needs: size 200 with 1/8 in ports is the compact entry of the range, stepping up through 300, 400 and 600 as air demand grows. Drain choice is differential-pressure (standard, as fitted here), automatic (A) or manual (M); element grade is 40 um standard or 5 um with W; gauges are round or square with MPa, psi or bar scales; threads come as PT standard or G/NPT to order; and a bracket is included with this unit. Because flow is published as curves rather than a single rated figure, send us your application and we will confirm sizing against the datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so we do not quote a number here. Send us your line pressure, port size and expected air demand and we will confirm the flow for GFR200C06LC1T from the datasheet before you order.
It marks the low-pressure regulator type. The catalogue does not quote an adjustment range for this variant, so we confirm the exact low-pressure range on request. Everything else decodes normally: 1/8 in NPT port, 40 um filter element, differential-pressure drain, round MPa gauge and included bracket.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.