The AirTAC GFR200C06LC1TK AirTAC Filter Regulator NPT1/8 Low-Pressure is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR200C06LC1TK is an AirTAC GFR-series filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This unit is the size 200 frame with a 1/8 in NPT port, built as the low-pressure type (L) for circuits that need a lower regulated pressure band; the exact adjustment range for the low-pressure version is not published, so confirm it with us. It carries the standard 40 um filter element, a differential-pressure drain on the bowl, a round pressure gauge scaled in MPa, a fitted reverse/check valve (K) and a mounting bracket. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing. The bowl on the 200 size is polycarbonate; only the 600 size uses aluminium alloy.
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with ports from 1/8 in to 1 in and PT, G (BSPP) or NPT threads, with manual, automatic or differential-pressure drains, 40 um or 5 um (W) filtration, gauge and scale choices, and an optional check valve. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application before ordering.
| Model | GFR200C06LC1TK AirTAC Filter Regulator NPT1/8 Low-Pressure |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Filtered, regulated air to the clamping cylinders on a CNC fixture, with the fitted check valve blocking reverse flow in the downstream circuit.
Clean, regulated supply feeding the control valves and small actuators on a carton-forming and sealing station, right at the drop where the air is used.
Low-pressure regulated air for a laboratory or pilot-scale rig that needs a modest, filtered supply without running a full three-piece F.R.L. set.
Choose the size by port and flow demand: 200 is the smallest GFR frame with a 1/8 in port; step up to 300, 400 or 600 when the line needs a larger port and more flow. This code fixes several choices: NPT thread (PT is the standard; G/BSPP and NPT are order options), 40 um filtration (5 um is available as code W), a differential-pressure drain (automatic A or manual M are the alternatives), a round gauge scaled in MPa (the embedded square gauge, or psi/bar scales, are alternatives), a fitted reverse/check valve (K) and an included bracket. The L in the code marks the low-pressure regulator type; its exact adjustment range is not published, so confirm it against your set pressure before ordering. Because flow is published as curves rather than a single rated figure, send us your application details and we will confirm sizing from the datasheet.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes GFR flow as curves, not as a single rated figure, so we do not quote a number here. Send us your application details and we will confirm the flow curve and sizing from the datasheet before you order.
GFR is the filter-regulator family and 200 is the size frame; 06 is the 1/8 in port and T is the NPT thread. L marks the low-pressure regulator type, C1 is the round gauge scaled in MPa, K is the fitted reverse/check valve, and no drain letter means the differential-pressure drain. The 40 um element is the standard filter grade (5 um is code W).
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.