The AirTAC GFR200C06LC2 AirTAC Filter Regulator PT1/8 Low-Pressure is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C06LC2 is a filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This 200-size unit is fitted with a PT1/8 (1/8 in) PT thread, a 40 um filter element, a differential-pressure drain (the default drain option) and a round gauge reading in psi. It is the low-pressure (L) regulator type, the polycarbonate (PC) bowl suits the -5 to 70 C non-freezing operating window, and maximum inlet pressure is 1.0 MPa (145 psi). A mounting bracket is included.
This is a genuine AirTAC part. The GFR series spans 200, 300, 400 and 600 sizes with ports from 1/8 to 1 in, and options include automatic or manual drains, a 5 um element (code W), square or round gauges with MPa, psi or bar scales, G or NPT threads and bracket variants. Flow is published as curves rather than a single rating, so ask us to confirm datasheet figures for your application before ordering.
| Model | GFR200C06LC2 AirTAC Filter Regulator PT1/8 Low-Pressure |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
On an assembly-cell fixture, the unit filters shop air to 40 um and holds a gentle regulated pressure on pneumatic clamps, with the round psi gauge giving the operator a local reading at the set.
At the point of use on a lab air ring main, it conditions air for pneumatic test rigs and bench instruments, draining condensate differentially and regulating supply within the low-pressure band the bench work needs.
Feeding gripper and pusher cylinders on a bottling line, the GFR200C06LC2 removes water and particulate before the actuators see it and regulates supply at the low pressures those light-duty motions require.
Choose the size by port and required flow: 200 is the compact step with the 1/8 in port fitted here, while 300, 400 and 600 carry larger ports and more flow. Drain choice matters: differential-pressure (this unit) is the default, automatic (A) empties without a pressure drop, and manual (M) is emptied by hand. The 40 um element is standard; specify W for 5 um where finer filtration is needed. This unit carries a round gauge with a psi scale; the embedded square gauge and MPa or bar scales are the alternatives. Thread is PT as standard - G (BSPP) and NPT are order options - and the bracket is included. Because flow is published as curves, not a single rating, send us your flow and pressure requirements and we will confirm sizing against the datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves, not a single rated figure, so we do not quote a number here. Send us your flow and pressure conditions and we will confirm the datasheet figures and the correct size for your application.
This GFR200C06LC2 carries the L code, so its regulator is the low-pressure variant rather than the standard type. The exact adjustment range for the low-pressure version is not published in the material we hold, so we confirm it on request; maximum inlet pressure is still 1.0 MPa (145 psi).
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.