verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR200 · Filter Regulator (filter + regulator in one body)

GFR200C06LC2WGK AirTAC Filter Regulator G1/8, 5 um

The AirTAC GFR200C06LC2WGK AirTAC Filter Regulator G1/8, 5 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$53.35 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR200C06LC2WGK AirTAC Filter Regulator G1/8, 5 um

The GFR200C06LC2WGK is an AirTAC GFR200 filter regulator: filtration and pressure regulation combined in a single body for compressed air. Water and particulate are spun out and caught in the polycarbonate bowl, which drains automatically by differential pressure as the element loads up. This configuration carries the 5 um (code W) element instead of the standard 40 um, the low-pressure regulator type, a round gauge reading in psi, and a built-in reverse/check valve so downstream pressure cannot back up through the unit. The G1/8 (1/8 in) G-thread port suits compact supply drops, and the mounting bracket is included.

This is a genuine AirTAC part. The GFR200 is the smallest size in the GFR range, which steps up through 300, 400 and 600 for larger ports and higher flow. Across the series you can order the standard 40 um or fine 5 um element, differential-pressure, automatic or manual draining, embedded square or external round gauges scaled in MPa, psi or bar, PT (standard), G or NPT threads, and the low-pressure regulator type fitted here. Flow is published as curves rather than a single rating, so ask us to confirm sizing figures from the datasheet for your application.

GFR200C06LC2WGK AirTAC Filter Regulator G1/8, 5 um Technical Specifications

ModelGFR200C06LC2WGK AirTAC Filter Regulator G1/8, 5 um
SeriesGFR200 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR200C06LC2WGK AirTAC Filter Regulator G1/8, 5 um

GFR200G-series filter regulator, 200 body — sets the port range.
C0Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR200 · See datasheet · 40 µm
One size upGFR300
Add lubricationGFC200-C0 (two-unit set)

Where the GFR200C06LC2WGK AirTAC Filter Regulator G1/8, 5 um Is Used

science

Analytical sample-line conditioning

On an analyzer skid, sample and purge air often needs gentle, stable low-pressure regulation plus fine particulate removal before it reaches sensors. The 5 um element, low-pressure regulator type and check valve in this unit keep the conditioned supply clean and hold the setpoint against backflow from the line.

precision_manufacturing

Compact pick-and-place heads

Small pneumatic grippers and mini cylinders on assembly cells typically run off 1/8 in drops. A GFR200 at each head filters condensed water and fine particles out of the shop air, regulates the supply to the low pressure these compact actuators need, and the round psi gauge gives the operator a local reading.

valve

Pilot-air supply for control valves

Positioners and pilot circuits on process control valves need clean, low-pressure instrument air. This filter regulator conditions the supply with 5 um filtration, holds the pilot pressure with the low-pressure regulator type, and the built-in check valve stops line backflow from disturbing the pilot setting.

Is the GFR200C06LC2WGK AirTAC Filter Regulator G1/8, 5 um the Right Unit?

Start with the port step: the GFR200 takes 1/8 in ports, and moving to GFR300/400/600 buys larger ports and more flow - match the step to your line's air demand rather than oversizing on guesswork. Choose the element grade: 40 um is the standard element, while the 5 um (W) fitted here protects finer downstream components. Choose the drain: differential-pressure (as here) drains only when the element loads up, automatic drains continuously, and manual needs a routine bleed. Choose the gauge and scale - the embedded square gauge is standard and the external round gauge fitted here reads psi; MPa and bar scales are also available. Thread is PT as standard, with G (as coded here) and NPT as order options; a bracket is included unless the J (no-bracket) code is specified. Note that this is the L low-pressure regulator type, and its exact adjustment range is not published - ask us to confirm it from the datasheet. Because flow is published only as curves and not as a single rated figure, send us your application details and we will confirm sizing before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR200C06LC2WGK AirTAC Filter Regulator G1/8, 5 um FAQ

AirTAC publishes G-series flow as curves rather than a single rated figure, so we do not quote a rated flow, Cv or SCFM number for this unit. Send us your application details - line pressure, downstream demand and port size - and we will confirm the sizing against the datasheet flow curves for you before you order.

The W in the code selects the optional 5 um filtration grade; the standard GFR element is 40 um. The finer 5 um element suits downstream components that are sensitive to fine particulate, such as pilot circuits, instruments and compact actuators. If your application only needs general water and particle knockdown, the 40 um standard grade is the usual choice - we can confirm the right grade from the datasheet on request.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR200C06LC2WGK AirTAC Filter Regulator G1/8, 5 um

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR200C06LC2WGK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.