The AirTAC GFR200C06LF1TK AirTAC Filter Regulator NPT1/8 Low-Pressure is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR200C06LF1TK is an AirTAC GFR-series filter regulator: one body that removes water and particulate from compressed air and regulates downstream pressure. This configuration is the 200 size with a 1/8 in NPT port, built as the low-pressure regulator type, with a 40 um filter element and a differential-pressure drain. A square pressure gauge scaled in MPa is fitted, a reverse (check) valve is included, and a mounting bracket comes with the unit. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing.
This is a genuine AirTAC part from the GFR range, which spans the 200, 300, 400 and 600 sizes with ports from 1/8 in up to 1 in, thread options PT (standard), G and NPT, drain choices, 40 um or 5 um filtration, and gauge or no-gauge variants. Flow for this series is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application.
| Model | GFR200C06LF1TK AirTAC Filter Regulator NPT1/8 Low-Pressure |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Feeding filtered, regulated low-pressure air to laboratory analyzers and sample-handling pneumatics where a compact 1/8 in connection is needed.
Supplying clean, regulated air to the pilot-control circuit of a packaging or labeling machine, with the built-in check valve holding downstream pressure if the supply dips.
Regulating supply to a small clamping or holding fixture on a production cell, with the 40 um element protecting downstream valves from water and particulate.
Match the size and port to the air demand of your circuit: this unit is the 200 size with a 1/8 in NPT connection, and larger sizes step up to bigger ports and greater flow capacity. For this family you also choose the drain type (differential-pressure as here, automatic, or manual), the filter grade (40 um standard, 5 um with code W), the gauge (embedded square or optional external round, scaled in MPa, psi or bar), the thread (PT standard, with G and NPT as order options), and whether a bracket is fitted. The L in this code marks the low-pressure regulator type; its exact adjustment range is not published, so confirm it with us. Flow for the G-series is published as curves, not a single rating, so send us your application details and we will confirm sizing against the datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the G-series as curves, not as a single rated figure, so we do not quote a number here. Tell us your application and air demand and we will confirm the flow from the datasheet on request before you order.
It marks the low-pressure regulator type, rather than the standard version. The exact adjustment range for the low-pressure type is not published in the catalogue sheet we work from, so ask us to confirm it on request. The rest of the code decodes as: 200 size, 1/8 in NPT port, square MPa gauge, differential-pressure drain, 40 um filter, check valve fitted, bracket included.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.