The AirTAC GFR200C06LF2G AirTAC Filter Regulator G1/8 Low-Pressure is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR200C06LF2G is an AirTAC GFR-series filter regulator: one body that first removes water and particulate from compressed air through a 40 um element, then regulates the downstream pressure. This size-200 unit carries a 1/8 in port with G (BSPP) thread, is built in the low-pressure type for circuits that run at reduced settings, and is fitted with an embedded square gauge reading in psi. The polycarbonate bowl uses differential-pressure drainage, so condensate is expelled automatically whenever the inlet pressure falls, and a mounting bracket is included for secure panel or frame fixing.
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, drain choices (differential-pressure, automatic or manual), an optional 5 um filter grade, gauge scale options and PT, G or NPT threads. Flow is published as curves rather than a single rating, so ask us to confirm the datasheet and sizing figures for your application on request.
| Model | GFR200C06LF2G AirTAC Filter Regulator G1/8 Low-Pressure |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Feeds filtered, low-pressure air to the gripper and vacuum-ejector circuit of a pick-and-place head on an electronics assembly line, where the 40 um element protects fine components from water and particulate carryover.
Supplies regulated air to the sealing-bar and clamp actuators of a small packaging machine, holding a gentle, stable setting that the low-pressure regulator type is chosen for, with the psi gauge giving the operator a direct readout.
Conditions the bench air feed to a laboratory rig or test station, removing condensate and grit through the 40 um element and letting a technician dial in a reduced working pressure read in psi on the square gauge.
Choose the size and port step against the air demand of the circuit: this unit is size 200 with a 1/8 in G-thread port, the smallest step in the range, with larger sizes 300/400/600 available for higher flow. Because flow is published as curves and not a single rated figure, ask us to confirm sizing against your application before ordering. Other real, decodable choices in this family: drain type (differential-pressure as fitted here, or automatic or manual), filter grade (40 um standard as here, or 5 um with code W), gauge scale (this unit reads psi; MPa and bar scales exist), thread family (PT is the standard, G and NPT are order options), and bracket inclusion. The L in this code marks the low-pressure regulator type; its exact adjustment range is not published in our data, so confirm it with us on request.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for this family as curves, not as a single rated number, so we do not quote a l/min, m3/h or SCFM figure. Tell us your application and we will confirm the flow and sizing data from the datasheet on request before you order.
The L marks the low-pressure regulator type, intended for circuits that run at reduced settings; its exact adjustment range is not published in our data, so confirm it with us. This unit's bowl uses differential-pressure drainage: condensate collected in the polycarbonate bowl is expelled automatically whenever the inlet pressure drops, with no manual draining routine needed.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.