The AirTAC GFR200C06LF2WG AirTAC Filter Regulator G1/8, 5 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR200C06LF2WG is an AirTAC GFR-series filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This configuration is built in size 200 with a G1/8 (BSPP) port, the optional 5 um (W) filtration element, a differential-pressure drain, and the low-pressure regulator type for circuits whose set pressure sits below the standard type's range (the exact adjustment window for this variant is confirmed on request). A square pressure gauge scaled in psi is fitted as standard, a mounting bracket is included, and the unit handles a maximum inlet pressure of 1.0 MPa (145 psi) at -5 to 70 C, non-freezing.
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with ports from 1/8 to 1 inch, drain choices (differential-pressure, automatic or manual), 40 um standard or 5 um (W) filtration, gauge scale options in MPa, psi or bar, and G or NPT thread variants as catalogue options. Flow is published as curves rather than a single rating, so ask us to confirm sizing and any datasheet figure for your application before ordering.
| Model | GFR200C06LF2WG AirTAC Filter Regulator G1/8, 5 um |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Conditioning the air feeding pneumatic clamps and swing cylinders on a machining-centre fixture, where filtered air and a steady, lower set pressure protect the clamp-and-unclamp sequence.
Filtering and regulating the supply to gripper and capper actuators on a bottling line, with the 5 um element helping keep fine valve orifices clear through continuous shifts.
Supplying clean, regulated air to sample-handling manifolds and pneumatic dispensers on a lab automation skid, where low set pressures and fine filtration are part of the spec.
Choose the size and port step (200 through 600, 1/8 to 1 inch) against the flow your line needs - the catalogue publishes flow as curves, not a single rated figure, so send us your demand and we will confirm the right size before you order. This unit carries the 5 um (W) element instead of the 40 um standard: pick 5 um where downstream instruments, precision valves or spray equipment need finer air. Drain here is differential-pressure (the default); automatic (A) and manual (M) versions exist if you prefer. The fitted square gauge reads in psi, with MPa and bar scales and an external round gauge as alternatives. Thread on this code is G (BSPP), with PT and NPT offered as catalogue options, and a mounting bracket is included.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes GFR flow as performance curves rather than a single rated figure, so we do not quote one number. Send us your line demand and operating conditions and we will confirm from the datasheet whether this size 200, G1/8 unit suits your application before you order.
The W code on this model selects the optional 5 um element for finer water and particulate removal where downstream instruments, precision valves or spray equipment need cleaner air. If your application tolerates coarser filtration, the 40 um standard version of the same size is the usual choice.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.