The AirTAC GFR200C06LF2WTK AirTAC Filter Regulator NPT1/8 Low-Pressure is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR200C06LF2WTK is an AirTAC GFR-series filter regulator: one body that removes water and particulate from compressed air and regulates downstream pressure. This configuration is the size 200 unit with a 1/8 in NPT port, the fine 5 um filter element (code W) instead of the standard 40 um, the low-pressure regulator type, and a differential-pressure drain that bleeds collected condensate automatically whenever the pressure differential across the element is high enough. A square pressure gauge scaled in psi is fitted, a reverse/check valve is built in, and a mounting bracket is included.
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in up to 1 in, a choice of differential-pressure, automatic or manual drain, 40 um or 5 um filtration, standard or low-pressure regulation, square or round gauges with MPa, psi or bar scales, and PT, G or NPT threads. We confirm flow and datasheet figures on request, since flow is published as curves rather than a single rating.
| Model | GFR200C06LF2WTK AirTAC Filter Regulator NPT1/8 Low-Pressure |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Point-of-use air preparation for a spray booth: the 5 um element keeps fine contamination out of the atomizing circuit while the low-pressure regulator holds a gentle, stable supply pressure to the guns.
Feeding the low-pressure actuation section of a cartoning or wrapping machine, where the check valve holds the downstream circuit and the psi gauge gives operators a direct local reading.
Conditioning the air feed to a lab bench or test rig that runs at reduced pressure: fine 5 um filtration protects sensitive instruments and the regulator trims the supply down to the working level.
Size the unit by the flow your line needs at the point of use: step up from size 200 (1/8 in here) to 300, 400 or 600 when the circuit demands more air, and match the port to your piping. Choose the drain to suit access: differential-pressure (this unit) needs no attention, automatic drains on a timer-free basis, and manual drain suits supervised installations. Pick the 5 um element (code W, fitted here) when downstream valves or instruments need finer air than the standard 40 um. Gauges can be square (fitted here, psi scale) or round, scaled in MPa, psi or bar; threads come as PT (standard), G or NPT (this unit, ordered as code T); a bracket is included. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so we do not quote one number. Send us your application details and we will confirm the flow and the full datasheet for this exact model on request before you order.
W is the fine filtration option: a 5 um element instead of the standard 40 um. This unit also has the differential-pressure drain (the blank drain code), which discharges collected condensate automatically when the pressure differential across the element rises - no manual draining routine is needed.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.