The AirTAC GFR200C06LF3WT AirTAC Filter Regulator 1/8 in NPT 5 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C06LF3WT is a size 200 filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in one body. This configuration has a 1/8 in NPT port, a 5 um filter element (code W), a differential-pressure drain on the bowl, and a low-pressure regulator type, so it suits circuits that run at reduced setpoints rather than full line pressure. An embedded square gauge with a bar scale is fitted so the setpoint can be read directly, and a mounting bracket is included. The bowl on this size is polycarbonate.
This is a genuine AirTAC part. The GFR range spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, a choice of differential-pressure, automatic or manual drain, 40 um standard or 5 um filtration, gauge and scale options, and PT, G or NPT threads. Flow is published as curves rather than a single rated figure, so ask us to confirm sizing and any datasheet figure against your application before ordering.
| Model | GFR200C06LF3WT AirTAC Filter Regulator 1/8 in NPT 5 um |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Feeds filtered, regulated air to a small benchtop press or crimping station, where the low-pressure regulator type holds a reduced setpoint for light clamping and forming work.
Supplies clean, regulated air to compact vacuum ejectors and gripper cylinders on a packaging machine, with the 5 um element protecting the small pilot valves upstream of the actuators.
Conditions the air feeding control valves and sensor-actuated cylinders on a filling or labelling station, where the bar-scale square gauge lets operators verify the setpoint at a glance.
Start with the port step: size 200 in 1/8 in is the smallest GFR frame, so check that the line's air demand sits comfortably within the flow curve for this size before committing. This unit carries the 5 um element (code W); the standard grade is 40 um, so choose 5 um where downstream valves or instruments need finer protection. Drain is differential-pressure, which bleeds the bowl automatically as pressure drops across the element; automatic (A) or manual (M) drains are alternatives if your duty cycle suits them better.
The regulator here is the low-pressure type (code L), intended for reduced setpoints; ask us to confirm its adjustment range for your circuit. The fitted square gauge reads in bar; MPa and psi scales and an external round gauge are order options. The thread on this code is NPT; PT is the standard thread and G (BSPP) is also available to order. A bracket is included, and no reverse/check valve is fitted on this code.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves, not as a single rated figure, so we do not quote a number here. Send us your line pressure, setpoint and air demand and we will confirm the flow from the datasheet and check the size 200, 1/8 in frame against your application before you order.
The W in the code GFR200C06LF3WT selects the 5 um filter grade instead of the 40 um standard element. Choose 5 um when downstream valves, cylinders or instruments need finer protection from particulate; if your application only needs bulk water and coarse dirt removal, the 40 um standard grade is the lower-restriction choice and is available as a separate code.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.