The AirTAC GFR200C06LJC1WT AirTAC Filter Regulator NPT1/8 Low-Pressure is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C06LJC1WT is a size 200 GFR-series filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in one body. This configuration carries a 5 um filtration element (the finer of the two catalogue grades), a differential-pressure drain that bleeds collected condensate as flow passes through, a fitted round pressure gauge scaled in MPa, and the low-pressure regulator type for circuits that run below standard line pressures. The port is 1/8 inch with NPT thread, and the unit ships without a mounting bracket.
This is a genuine AirTAC part from the GFR line, which spans sizes 200, 300, 400 and 600 with port sizes from 1/8 to 1 inch, a choice of differential-pressure, automatic or manual drain, 40 um standard or 5 um fine filtration, standard or low-pressure regulation, gauge and scale options, and PT, G or NPT threads. Because flow is published as curves rather than a single rating, we confirm sizing and datasheet figures for your application on request.
| Model | GFR200C06LJC1WT AirTAC Filter Regulator NPT1/8 Low-Pressure |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Feeding clean, low-pressure air to laboratory analysers and sampling systems, where the 5 um element protects sensitive pneumatic components and the low-pressure type matches the instrument's supply requirement.
Regulating and filtering supply air to compact pneumatic clamps and small actuator circuits on assembly benches, with the 1/8 inch NPT port matching the compact tooling manifold.
Conditioning air for the low-pressure pilot and control legs of packaging and labelling equipment, with the MPa gauge giving operators a direct reading at the setpoint.
Start with the port step: this unit is size 200 with a 1/8 inch NPT port, the smallest in the GFR range, so step up to size 300, 400 or 600 if your line uses larger piping or higher flow. This example is the low-pressure regulator type, so choose it only for circuits that run below standard regulated pressures; the standard type covers general duty. The 5 um element (code W) suits air that feeds sensitive components, while the standard 40 um element suits general supply - both are decodable options in this family. Drain is differential-pressure here; automatic or manual drain are the alternatives. The fitted round gauge reads in MPa, with psi and bar scales available, and PT is the standard thread with G and NPT as order options.
Because catalogue flow is published only as curves and not as a single rated figure, ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so we do not quote a number here. Tell us your line pressure, set pressure and expected air consumption, and we will confirm the correct size and the flow figures from the datasheet for your application before you order.
The W in the code specifies the 5 um filtration grade, the finer alternative to the standard 40 um element, which suits air feeding sensitive components. The L specifies the low-pressure regulator type, intended for circuits running below standard regulated pressures; its exact adjustment range is not published in the material we hold, so we confirm it on request. The C1 specifies the fitted round gauge with an MPa scale.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.