The AirTAC GFR200C06LJC2 AirTAC Filter Regulator PT1/8 Low-Pressure is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR200C06LJC2 is an AirTAC GFR-series filter regulator: it removes water and particulate from compressed air and reduces pressure to the working setpoint in a single body. This 200-size unit is fitted with PT1/8 ports, a 40 um standard filtration element and a differential-pressure drain, and the polycarbonate bowl lets you see the condensate level. It is the low-pressure regulator variant, supplied with an external round gauge scaled in psi and without a mounting bracket. Maximum inlet pressure is 1.0 MPa (145 psi) and the operating temperature range is -5 to 70 C (non-freezing).
This is a genuine AirTAC part. The GFR family spans 200, 300, 400 and 600 sizes with ports from 1/8 to 1 inch, PT, G(BSPP) or NPT threads, 40 um or 5 um (W) filtration, differential-pressure, automatic or manual drains, and embedded square or external round gauges in MPa, psi or bar scales. Flow is published as curves rather than a single rated figure, so ask us to confirm sizing and datasheet details for your application on request.
| Model | GFR200C06LJC2 AirTAC Filter Regulator PT1/8 Low-Pressure |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Conditioning and stepping down supply air to pilot valves, positioners and I/P devices on a process skid, with the psi round gauge giving a readable setpoint at the panel.
Feeding filtered, reduced-pressure air to the small cylinders and air jets on a cartoning or filling station where the 1/8 in port matches the machine's air circuit.
Supplying clean, regulated low-pressure air to bench-top instruments and test rigs, where the 40 um element and visible polycarbonate bowl keep the supply tidy and easy to check.
Your real choices on this family are the size and port step, the drain type, the filter grade, the gauge and its scale, the thread and the bracket. This code fixes them: 200 size with PT1/8 ports for compact circuits, 40 um filtration (choose 5 um, code W, for finer protection), a differential-pressure drain (automatic, code A, or manual, code M, are the alternatives), an external round gauge scaled in psi (an embedded square gauge, or MPa or bar scales, are the other options), PT thread with G and NPT available to order, and no mounting bracket. Match the 200 size and its 1/8 in port to the pipe and the air demand of the circuit.
Because AirTAC publishes flow as curves and not as a single rated figure, we do not quote a flow number here. Send us your application details and we will confirm the sizing against the datasheet curves before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for this family as curves, not as a single rated figure, so we do not quote a number. Tell us your line pressure, setpoint and downstream demand and we will confirm the flow from the datasheet curves on request before you order.
It marks the low-pressure regulator type. The published adjustment ranges apply to the standard type; the exact range for this low-pressure variant is not in our current data, so please confirm it with us if your setpoint is critical. The rest of the code decodes as: 200 size, PT1/8 port, differential-pressure drain, 40 um element, no bracket, and an external round gauge scaled in psi.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.