verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR200 · Filter Regulator (filter + regulator in one body)

GFR200C06LJC2T AirTAC Filter Regulator NPT1/8 Low-Pressure

The AirTAC GFR200C06LJC2T AirTAC Filter Regulator NPT1/8 Low-Pressure is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$40.90 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR200C06LJC2T AirTAC Filter Regulator NPT1/8 Low-Pressure

The AirTAC GFR200C06LJC2T is a size 200 filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in one compact body. This configuration has a 1/8 in NPT port, the low-pressure regulator type, a 40 um standard filter element, a differential-pressure drain on the bowl, and a round pressure gauge reading in psi. The bowl is fitted without a mounting bracket. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing). As a low-pressure type, its exact adjustment range is not published in the general table - we confirm it from the datasheet on request.

This is a genuine AirTAC part. The GFR family is available in sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, a choice of differential-pressure, automatic or manual drains, a 40 um standard or 5 um (W) filter grade, embedded square or external round gauges in MPa, psi or bar scales, and PT, G or NPT threads. Flow is published as curves rather than a single rated figure, so ask us to confirm sizing and datasheet figures for your application before ordering.

GFR200C06LJC2T AirTAC Filter Regulator NPT1/8 Low-Pressure Technical Specifications

ModelGFR200C06LJC2T AirTAC Filter Regulator NPT1/8 Low-Pressure
SeriesGFR200 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR200C06LJC2T AirTAC Filter Regulator NPT1/8 Low-Pressure

GFR200G-series filter regulator, 200 body — sets the port range.
C0Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR200 · See datasheet · 40 µm
One size upGFR300
Add lubricationGFC200-C0 (two-unit set)

Where the GFR200C06LJC2T AirTAC Filter Regulator NPT1/8 Low-Pressure Is Used

science

Benchtop and pilot-scale pneumatic test rigs

Laboratory and pilot rigs running small air cylinders or test fixtures at reduced pressure use the 1/8 in NPT connection and low-pressure regulator to hold a gentle, stable supply, with the 40 um element keeping particulate out of sensitive instruments.

valve

Low-pressure actuation of small process valves

On filling, dosing and small packaging lines, pneumatic pilot valves and compact actuators often need a lower supply pressure than the main header delivers - this filter regulator cleans the air and steps the pressure down right at the valve manifold.

precision_manufacturing

Air-spray and air-blow stations at light pressure

Spray-gun stations, cooling air jets and light-duty blow-off points on assembly benches benefit from filtered air at a low, repeatable setting; the round psi gauge lets operators read and reset the exact pressure for the job.

Is the GFR200C06LJC2T AirTAC Filter Regulator NPT1/8 Low-Pressure the Right Unit?

Start with the port: this unit steps down to 1/8 in NPT, the smallest G-series connection, so match it to the line size and the flow your circuit actually needs - if your demand sits near the top of a 1/8 in line, step up to a size 300 body instead. This is the low-pressure regulator type, chosen where the downstream setpoint sits in the lower part of the working range; the standard type remains available in the same family if your setpoint is higher. The 40 um element is the standard grade; specify the W suffix for 5 um where finer particulate removal matters. Drain is differential-pressure here (it bleeds as the pressure differential builds); choose automatic (A) for unattended installs or manual (M) where an operator drains on schedule. The round psi gauge is fitted; square embedded gauges and MPa or bar scales are alternatives. Thread is NPT on this unit - PT is the standard catalogue thread and G (BSPP) is also orderable. No mounting bracket is included on this code; bracketed versions exist. Flow is published as curves, not a single rating, so send us your application details and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR200C06LJC2T AirTAC Filter Regulator NPT1/8 Low-Pressure FAQ

AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so there is no one rated-flow number we can honestly quote for this unit. Tell us your line pressure, setpoint and air demand and we will confirm the sizing against the datasheet curves on request before you order.

The L in the code marks the low-pressure regulator type, intended where the downstream setpoint sits in the lower part of the working range; the standard type covers the full adjustment range. For this low-pressure variant the exact adjustment range is not published in the general table - we confirm it from the datasheet on request. Everything else decodes normally: 1/8 in NPT port, 40 um filter, differential-pressure drain, round psi gauge, 1.0 MPa (145 psi) maximum inlet, -5 to 70 C.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR200C06LJC2T AirTAC Filter Regulator NPT1/8 Low-Pressure

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR200C06LJC2T and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.