The AirTAC GFR200C06LJC2W AirTAC Filter Regulator 1/8 in PT is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR200C06LJC2W is an AirTAC GFR200 filter regulator: one body that removes water and particulate from compressed air and sets downstream pressure. This configuration is the size 200 unit with a 1/8 in PT threaded port, a 5 um filter element (code W) for finer filtration than the standard 40 um grade, and a differential-pressure drain that bleeds collected condensate automatically whenever the pressure differential across the element is high enough. It is the low-pressure type, intended for circuits that run below standard line pressures, and the exact adjustment range for this variant is confirmed on request. A round pressure gauge reading in psi is fitted, the maximum inlet pressure is 1.0 MPa (145 psi), and the operating temperature range is -5 to 70 C (non-freezing). The bowl is metal, and no mounting bracket is included in this code.
This is a genuine AirTAC part. The GFR series is available in sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, a choice of PT, G (BSPP) or NPT threads, 40 um or 5 um filtration, differential-pressure, automatic or manual drains, and gauge options. Flow is published as curves rather than a single rated figure, so we confirm the datasheet and flow figures for your application on request.
| Model | GFR200C06LJC2W AirTAC Filter Regulator 1/8 in PT |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Supplies filtered, regulated air to the pneumatic clamps and tool-change cylinders on a machining centre, where the 5 um element helps protect close-tolerance valves from particulate and water.
Feeds the pick-and-place and sealing actuators on a packaging line, holding a steady low regulated pressure so carton-forming and sealing sequences repeat consistently shift after shift.
Conditions the compressed air feeding bench-top lab and test instruments, where the 5 um grade and a low regulated setting suit sensitive pneumatic controls and the psi gauge gives a direct local reading.
Start with the port step: size 200 with a 1/8 in PT port suits compact circuits; step up to 300, 400 or 600 when the circuit needs a larger port and more flow capacity. This unit already carries the finer 5 um element (W); the standard grade is 40 um if your application does not need the finer element. The differential-pressure drain in this code needs no manual attention under normal duty; choose automatic (A) or manual (M) drain codes where the installation calls for them. The fitted round gauge reads in psi; square embedded gauges and MPa, psi or bar scales are the other gauge choices. PT is the standard thread here, with G (BSPP) and NPT available as order options, and this code omits the mounting bracket (J).
Because flow for the GFR series is published as curves and not as a single rated number, ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so we do not quote a rated flow number. Tell us your application and we will confirm the flow figures from the datasheet on request before you order.
The W in the code specifies the 5 um filter grade instead of the standard 40 um, for finer removal of particulate ahead of sensitive downstream equipment. The blank drain position is the differential-pressure type, which discharges collected condensate automatically as the pressure differential across the element rises, with no manual draining in normal duty.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.