The AirTAC GFR200C06LJC2WT AirTAC Filter Regulator NPT 1/8 in, 5 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C06LJC2WT is a size 200 filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This configuration has a 1/8 in NPT port, a fine 5 um filter element (the 40 um standard element is the alternative), a differential-pressure drain that bleeds collected condensate automatically as flow passes through, a low-pressure regulator type, and an external round gauge reading in psi. No mounting bracket is fitted. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing); the polycarbonate bowl suits this size (600-size units use an aluminium alloy bowl).
This is a genuine AirTAC part. The GFR filter-regulator family spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, and is ordered with choices of drain type, filter grade, gauge style and scale, thread (PT standard, with G and NPT as catalogue options), bracket and reverse/check valve. Flow is published as curves rather than a single rating, so ask us to confirm sizing and any datasheet figure against your application before ordering.
| Model | GFR200C06LJC2WT AirTAC Filter Regulator NPT 1/8 in, 5 um |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
On a machining cell where low-pressure clamping cylinders hold aluminium workpieces, this filter regulator cleans the shop air to 5 um and holds a reduced, low-pressure setting at the fixture, with the psi gauge giving the operator a direct local readout.
Before empty PET bottles reach the filler, air knives and blow-off nozzles need clean, dry-ish air at a gentle reduced pressure so labels and lightweight containers are not disturbed. The 5 um element protects the nozzles and the low-pressure type suits the modest setting.
A lab bench running small pneumatic stirrers and actuators off a house compressed-air line benefits from fine 5 um filtration and a stable low regulated pressure, with the differential-pressure drain handling condensate without manual attention between experiments.
Step through the decodable choices in order. Size 200 with a 1/8 in NPT port is the smallest step in the GFR range; move up to 300/400/600 for larger ports and higher flow demand, and have us check the published flow curves against your consumption rather than guessing. Drain: this unit uses the differential-pressure drain (the default); automatic (code A) or manual (code M) drains are the alternatives where bleed-through or a hands-on drain point is preferred. Filter grade: the fitted 5 um element (code W) protects sensitive components; choose the standard 40 um where coarser filtration is acceptable. Gauge: this configuration carries the external round gauge with a psi scale; an embedded square gauge with MPa, psi or bar scales is the standard alternative. Thread: NPT is fitted here as a catalogue option; PT is the standard thread and G (BSPP) is also available. Bracket: none is fitted (code J); a bracket can be ordered where panel or wall mounting is needed.
One honest note before you order: AirTAC publishes flow for this family as curves, not a single rated figure, and the exact regulation range of the low-pressure (L) type is not stated as a single number in the material we hold. Send us your line pressure, setpoint and air consumption and we will confirm suitability from the datasheet before you commit.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR family as curves rather than a single rated figure, so we do not quote a rated flow number. Send us your line pressure, required downstream pressure and air consumption, and we will confirm sizing from the datasheet curves on request before you order.
The code spells it out: W selects the optional 5 um filter element instead of the 40 um standard, and C2 selects the external round gauge with a psi scale (the embedded square gauge with MPa, psi or bar scales is the standard alternative). The L marks the low-pressure regulator type, J means no mounting bracket is fitted, and T is the NPT thread option - PT is the standard thread and G (BSPP) is also available to order.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.