The AirTAC GFR200C06LJC2WTK AirTAC Filter Regulator NPT1/8 5 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR200C06LJC2WTK is an AirTAC GFR200 filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This configuration is the 200 size with a 1/8 in NPT port, the finer 5 um filtration element (code W), a differential-pressure drain, the low-pressure regulator type, a round pressure gauge with a psi scale, and a built-in reverse (check) valve; it is supplied without a mounting bracket. The bowl on this size is polycarbonate (PC). Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing).
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with ports from 1/8 to 1 in, and options for drain type (differential-pressure, automatic or manual), filter grade (40 um standard, 5 um with W), gauge style and scale (MPa, psi or bar), thread (PT standard; G and NPT to order), bracket and reverse valve. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application.
| Model | GFR200C06LJC2WTK AirTAC Filter Regulator NPT1/8 5 um |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Filtering and holding a steady reduced pressure to the clamping cylinders of a CNC or dedicated-machine fixture, with the fitted reverse valve blocking backflow in the line.
Feeding low-pressure test rigs and instrument air circuits where the 5 um element protects sensitive components and the psi-scale round gauge reads the set point directly.
Supplying filtered, regulated air to small cylinders and air jets on packaging or conveyor lines that run at reduced pressure rather than full line pressure.
The real choices you can decode: step the size (200/300/400/600) and port (1/8 to 1 in) to match your line; pick the drain - differential-pressure (the default, working from the pressure drop across the element), automatic, or manual; choose 40 um standard filtration or 5 um (W) for finer protection; select gauge style (embedded square as standard, external round optional) and scale (MPa, psi or bar); order PT, G or NPT thread; and decide on bracket and reverse/check valve. This unit is the low-pressure type, without a bracket, with a round psi gauge and the check valve fitted. Flow is published as curves, not a single rating - send us your pressure and flow requirements and we will confirm sizing against the datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes GFR flow as curves rather than a single rated figure, so we do not quote a number here. Tell us your line pressure, set pressure and required flow, and we will confirm from the datasheet whether the GFR200 at 1/8 in NPT suits your application before you order.
The L code marks the low-pressure regulator variant, intended for circuits set below standard line pressure. The catalogue does not publish an exact adjustment range for this variant, so we will confirm the range from the datasheet on request. Everything else decodes normally: 1/8 in NPT port, 5 um element, differential-pressure drain, round psi gauge and fitted reverse valve.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.