The AirTAC GFR200C06LJC3WT AirTAC Filter Regulator NPT1/8 is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C06LJC3WT is a GFR-series filter regulator: it removes water and particulate from compressed air and holds downstream pressure at a set point in one compact body. This size 200 unit has a 1/8 in NPT port, a 5 um filter element (the finer of the two published grades), a differential-pressure drain, a round pressure gauge with bar scale, and the low-pressure regulator type. The polycarbonate bowl suits the non-freezing -5 to 70 C working range, and maximum inlet pressure is 1.0 MPa (145 psi).
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with port sizes from 1/8 to 1 in, drain choices (differential-pressure, automatic or manual), 40 um or 5 um filtration, standard or low-pressure regulation, gauge and thread options, and bracket choices. AirTAC publishes flow for these units as curves rather than a single rated figure, so ask us to confirm flow and datasheet details for your application.
| Model | GFR200C06LJC3WT AirTAC Filter Regulator NPT1/8 |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Feeding filtered, regulated air to the clamp cylinders on a light-duty pneumatic press fixture, where the low-pressure regulator type is selected for a reduced set-point circuit and the 5 um element protects the downstream control valves.
Point-of-use conditioning for the flap-fold and tape-head cylinders on a packaging conveyor, with the round bar-scale gauge giving operators a local pressure reading at the machine.
Conditioning instrument air on a lab or pilot-plant skid, where the differential-pressure drain clears collected water during operation and the compact 200 size fits tight panel space.
Choose the size and port step (200 through 600, 1/8 to 1 in) against the air demand of the circuit; this unit is the 200 size with a 1/8 in NPT port. Within GFR you can pick drain type (differential-pressure, automatic or manual), filter grade (40 um standard or 5 um with W), standard or low-pressure regulation, gauge style and scale (embedded square or external round; MPa, psi or bar), thread (PT standard, G or NPT to order) and bracket. Because flow is published as curves rather than a single rating, send us your application details and we will confirm sizing before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for GFR units as curves rather than a single rated figure, so we do not quote a number here. Send us your application details and we will confirm the flow and datasheet figures for this exact model on request.
The L in the code marks the low-pressure regulator variant rather than the standard one. The exact adjustment range for the low-pressure type is not published in the material we hold, so tell us your set point and we will verify suitability on request. Maximum inlet pressure remains 1.0 MPa (145 psi).
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.