The AirTAC GFR200C06LJC3WTK AirTAC Filter Regulator NPT1/8 Low-Pressure is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C06LJC3WTK is a filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This 200-size unit has a 1/8 in NPT port, a 5 um filtration element (the finer of the two published grades), a differential-pressure drain that bleeds collected condensate automatically when the pressure differential rises, and a low-pressure regulator type. It is supplied without a mounting bracket, and a reverse/check valve is fitted so downstream pressure is held if the supply is interrupted. The round pressure gauge on this configuration reads in bar. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing). The bowl on this 200-size unit is polycarbonate; only the 600 size uses an aluminium alloy bowl.
This is a genuine AirTAC part from the GFR series, which spans 200, 300, 400 and 600 sizes with port steps from 1/8 in to 1 in, a choice of differential-pressure, automatic or manual drains, 40 um standard or 5 um (W) filtration, gauge and thread options, and standard or low-pressure regulator types. Flow is published as curves rather than a single rated figure, so we confirm the datasheet and flow figures for your application on request.
| Model | GFR200C06LJC3WTK AirTAC Filter Regulator NPT1/8 Low-Pressure |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Feeding filtered, regulated air to hand-held pneumatic screwdrivers and small clamps at a bench where the process runs below standard line pressure and needs the low-pressure regulator type.
Conditioning supply air to an analytical instrument or sample-prep panel, where the 5 um element protects sensitive pneumatic components and the bar-scale gauge allows a setpoint to be checked at a glance.
Filtering and regulating the actuation air for pneumatic gates and diverters on a dust-extraction duct, with the fitted check valve holding the gate position if shop air drops.
Size and port set the flow capacity: this unit is 200 size with a 1/8 in NPT port, the smallest step in the GFR range, so step up to 300/400/600 if your line needs more flow. Filtration is 5 um here (code W) against the 40 um standard - choose 5 um where downstream valves or instruments need finer protection. The drain is differential-pressure (the default); automatic (A) and manual (M) drains are available if your duty cycle or maintenance routine suits them better. The regulator on this code is the low-pressure type; its exact adjustment range is not published in the material we hold, so confirm it with us before ordering. The gauge is the external round type reading in bar; the embedded square gauge is the standard fitting, with MPa, psi and bar scales available. Thread options are PT (standard), G (BSPP) and NPT - this code carries NPT. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves, not as a single rated figure, so we do not quote a rated flow number. Send us your application details and we will confirm the flow figures from the datasheet so you can size the unit correctly before ordering.
The W in the code GFR200C06LJC3WTK selects the 5 um filtration grade instead of the 40 um standard, giving finer protection for downstream equipment. The K at the end of the code means a reverse/check valve is fitted, which holds downstream pressure if the air supply is interrupted. Both are catalogue options you can include or omit when ordering.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.