The AirTAC GFR200C06LJF1T AirTAC Filter Regulator NPT1/8, Low-Pressure is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C06LJF1T is a GFR-series filter regulator: one body that removes water and particulate from compressed air and regulates downstream pressure. This size 200 configuration has 1/8 in NPT ports, the low-pressure regulator type, a 40 um standard filtration element, a differential-pressure drain and an embedded square gauge scaled in MPa. Maximum inlet pressure is 1.0 MPa (145 psi), the working temperature range is -5 to 70 C (non-freezing), the bowl for this size is polycarbonate, and the unit is supplied without a mounting bracket.
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with ports from 1/8 in up to 1 in, and the catalogue options include a 5 um filter element (code W), automatic or manual drains, gauge scales in psi or bar as well as MPa, an external round gauge, an optional mounting bracket, and G (BSPP) or NPT threads alongside the PT standard. AirTAC publishes flow as curves rather than a single rated figure, so ask us and we will confirm the datasheet figures for your application.
| Model | GFR200C06LJF1T AirTAC Filter Regulator NPT1/8, Low-Pressure |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Feeds filtered air to clamp cylinders on a small assembly fixture, keeping moisture and particulate out of the clamp circuit while the operator holds a low, repeatable set pressure.
Conditions the compressed air feeding bench-top laboratory apparatus such as agitators, air bearings or spray nozzles, where a low set pressure and filtered supply are part of the setup.
Sits upstream of a compact gripper or pick-and-place module on a packaging line, filtering the supply and letting the technician dial in the low working pressure the module needs.
Size and port are the first choice: GFR units step through sizes 200, 300, 400 and 600, each opening onto larger ports from 1/8 in up to 1 in, so choose the step whose flow curve covers your demand - we confirm curve figures on request rather than quoting a single rating. This code already fixes several choices: 1/8 in NPT ports (PT is the AirTAC standard thread, with G and NPT as order options), the low-pressure regulator type, the 40 um standard element (5 um available as code W) and the differential-pressure drain (automatic and manual drains are the alternatives).
The gauge on this unit is the embedded square type scaled in MPa, with psi or bar scales and an external round gauge available as options. A mounting bracket can be ordered separately, since this J-coded unit comes without one. If your set pressure sits below the standard regulator band, the low-pressure (L) type shown here is the variant to specify - we confirm its exact adjustment window on request.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so we do not quote a number here. Send us your line pressure, set pressure and air demand, and we will confirm the datasheet curve figures against your application before you order.
PT is the standard thread for the GFR series, and G (BSPP) and NPT versions are catalogue options identified by the thread suffix in the code. This unit's 06 position specifies the 1/8 in NPT port; order the corresponding G or PT suffix if your pipework uses those threads.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.