verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR200 · Filter Regulator (filter + regulator in one body)

GFR200C06LJF1WT AirTAC Filter Regulator NPT1/8, 5 um

The AirTAC GFR200C06LJF1WT AirTAC Filter Regulator NPT1/8, 5 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$40.88 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR200C06LJF1WT AirTAC Filter Regulator NPT1/8, 5 um

The GFR200C06LJF1WT is an AirTAC GFR200 filter regulator: a 5 um filter element and a low-pressure regulator combined in one body. This configuration comes with a differential-pressure drain, a metal bowl, an embedded square gauge scaled in MPa, and no mounting bracket. It connects on a 1/8 in NPT port, accepts up to 1.0 MPa (145 psi) inlet pressure, and operates from -5 to 70 C in non-freezing conditions.

This is a genuine AirTAC part. The GFR family spans sizes 200 to 600 with ports from 1/8 to 1 in, a choice of 40 um or 5 um filtration, differential-pressure, automatic or manual drains, standard or low-pressure regulation, square or round gauges with MPa, psi or bar scales, and PT, G or NPT threads. Flow figures are published as curves rather than a single rating, so ask us to confirm sizing and datasheet details for your application.

GFR200C06LJF1WT AirTAC Filter Regulator NPT1/8, 5 um Technical Specifications

ModelGFR200C06LJF1WT AirTAC Filter Regulator NPT1/8, 5 um
SeriesGFR200 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR200C06LJF1WT AirTAC Filter Regulator NPT1/8, 5 um

GFR200G-series filter regulator, 200 body — sets the port range.
C0Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR200 · See datasheet · 40 µm
One size upGFR300
Add lubricationGFC200-C0 (two-unit set)

Where the GFR200C06LJF1WT AirTAC Filter Regulator NPT1/8, 5 um Is Used

precision_manufacturing

Pneumatic clamping on a CNC fixture

Filtered, low-pressure regulated air holds workpieces in soft-jaw clamps and swing cylinders on a machining fixture, with the 5 um element protecting the clamp valve seats from particulate.

conveyor_belt

Blow-off nozzles on a bottling line

A low-pressure regulated feed to air-knife nozzles clears droplets from bottles travelling on a conveyor, while the differential-pressure drain bleeds collected water without stopping the line.

science

Purge air to a laboratory reactor

Clean 5 um air at a low, stable setting purges a laboratory reactor or analyser enclosure, with the embedded square MPa gauge giving a local pressure reading at the panel.

Is the GFR200C06LJF1WT AirTAC Filter Regulator NPT1/8, 5 um the Right Unit?

Size 200 with a 1/8 in NPT port suits compact circuits; step up through sizes 300, 400 and 600 as the required flow grows. This unit is already specified with the 5 um element (40 um is the standard alternative), a differential-pressure drain, low-pressure regulation and an embedded square MPa gauge; an external round gauge and psi or bar scales are order options, as are PT and G threads in place of NPT. No mounting bracket is included with this code. Flow is published as curves, not a single rated figure, so send us your pressure and flow requirements and we will confirm the right size before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR200C06LJF1WT AirTAC Filter Regulator NPT1/8, 5 um FAQ

AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so no rated number is quoted here. Tell us your working pressure and required flow and we will confirm against the datasheet whether this size 200, 1/8 in unit is correctly sized for your circuit.

The W in the code selects the 5 um filter element instead of the 40 um standard grade, which suits circuits with fine valves or instruments. Regulation on this unit is the low-pressure type; its exact setting range is not published, so ask us to confirm it for your application.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR200C06LJF1WT AirTAC Filter Regulator NPT1/8, 5 um

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR200C06LJF1WT and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.