The AirTAC GFR200C06LJF2K AirTAC Filter Regulator PT1/8 Low-Pressure is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C06LJF2K is a filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This size 200 unit has a PT1/8 port, the low-pressure regulator type (code L), a 40 um standard filter element and a differential-pressure drain, the default drain type for this family. An embedded square gauge with a psi scale is fitted, along with a reverse (check) valve (code K); the unit is supplied without a mounting bracket (code J).
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with ports from 1/8 in to 1 in, and catalogue options including automatic or manual drains, a 5 um filter element (code W), MPa or bar gauge scales, an external round gauge, and G (BSPP) or NPT threads in place of the standard PT. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing. The adjustment range of the low-pressure type is not published in our catalogue data, and flow is published as curves rather than a single rating, so ask us to confirm both on request before ordering.
| Model | GFR200C06LJF2K AirTAC Filter Regulator PT1/8 Low-Pressure |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Point-of-use air treatment for small pneumatic cylinders and grippers on an electronics assembly bench, where the low-pressure regulator type and the 1/8 in PT port match compact actuator circuits.
Conditioning the instrument air feed inside an analytical or test cabinet: the 40 um element strips water and particulate before the low-pressure regulator sets the supply for sensitive pneumatic controls.
Feeding a filtered, low-pressure pilot circuit in a packaging machine's pneumatic control panel, with the built-in reverse (check) valve and the square psi gauge giving a local setpoint readout.
Every choice in this unit is decodable from the code. Size 200 with a PT1/8 port is the smallest step in the family; step up through 300, 400 and 600 when the application needs a larger port and more flow. Drain type is a real choice: differential-pressure (this unit, the default), automatic (code A) or manual (code M). Filter grade is 40 um as fitted here, or 5 um with code W where finer particulate removal is needed. The gauge is an embedded square gauge with a psi scale (code F2); MPa or bar scales and an external round gauge are the alternatives. Thread is standard PT, with G (BSPP) and NPT as order options. This unit is the low-pressure type (code L), includes a reverse (check) valve (code K) and omits the mounting bracket (code J). Flow is published as curves, not a single rated figure, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes GFR flow as curves rather than a single rated figure, so we do not quote a rated flow, Cv or SCFM for this unit. Send us your application details and we will confirm the sizing and the datasheet flow curves on request.
This unit has the differential-pressure drain, the default drain type for the GFR family. Code A gives an automatic drain and code M a manual drain; all three are catalogue options across the GFR range, so you can select the drain behavior that suits your installation.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.