The AirTAC GFR200C06LJF2WK AirTAC Filter Regulator PT1/8 Low-Pressure is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C06LJF2WK is a size-200 filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in one body. This configuration is built for low-pressure service, with a fine 5 um filter element (code W), a differential-pressure drain on the bowl, an embedded square gauge reading in psi, and a reverse/check valve fitted to hold downstream pressure. The port is PT1/8 (1/8 in PT thread), and no mounting bracket is included with this version.
This is a genuine AirTAC part from the GFR series, which spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in up to 1 in, a choice of drain types, 40 um or 5 um filtration, gauge styles and scales, and PT, G or NPT threads. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing). Flow is published as curves rather than a single rating, so ask us to confirm sizing and datasheet figures for your application before ordering.
| Model | GFR200C06LJF2WK AirTAC Filter Regulator PT1/8 Low-Pressure |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Feeding a blow-off nozzle strip that clears dust from cartons before sealing, where the line runs at reduced pressure and the 5 um element keeps fine particulate out of the nozzles.
Regulating gentle clamp force on a router or press fixture that must not mar the workpiece, with the check valve holding the set pressure if supply dips mid-cycle.
Supplying clean, low-pressure air to a small-scale coating or test rig, where fine 5 um filtration and a local psi gauge let the operator verify the setting at the point of use.
Choose the GFR size by matching the port step to your line: this unit is size 200 with a PT1/8 port, and the series steps up through 300, 400 and 600 as flow demand grows. Drain type is a real choice: differential-pressure (as fitted here), automatic, or manual. Filter grade is 40 um standard or 5 um with code W - this unit carries the 5 um element for finer protection. Gauges are embedded square as standard with optional external round gauges in MPa, psi or bar scales; this one reads psi. Thread is PT as standard, with G and NPT available as order options, and a bracket can be added where this no-bracket version does not suit the mounting.
Because flow for this series is published as curves and not as a single rated figure, we do not quote a flow number here. Send us your application details and we will confirm the sizing against the datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for this series as curves rather than a single rated figure, so we do not quote a flow number. Tell us your application and line conditions and we will confirm the sizing from the datasheet on request.
The L in the code marks the low-pressure regulator variant, intended for service below the standard setting range. The exact setting range for this variant is not published in the general listing, so we confirm it from the datasheet on request. The unit otherwise carries a 5 um filter element, a differential-pressure drain, a square psi gauge and a fitted check valve.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.