AirTAC GFR200 · Filter Regulator (filter + regulator in one body)

GFR200C06LJF2WTK AirTAC Filter Regulator NPT1/8

The AirTAC GFR200C06LJF2WTK AirTAC Filter Regulator NPT1/8 is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$52.27 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR200C06LJF2WTK AirTAC Filter Regulator NPT1/8

The GFR200C06LJF2WTK is an AirTAC GFR200 filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in one body. This configuration is built for a 1/8 in NPT port, carries the 5 um filter element (the finer of the two published grades), uses a differential-pressure drain that discharges collected condensate automatically at low flow, and is the low-pressure regulator type for circuits that run at reduced settings. A square pressure gauge scaled in psi is fitted, a reverse/check valve is installed, and the unit is supplied without a mounting bracket.

This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with ports from 1/8 to 1 in, a choice of differential-pressure, automatic or manual drains, 40 um standard or 5 um (W) filtration, gauge scales in MPa, psi or bar, and PT, G or NPT threads. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing. Rated flow is published as curves rather than a single figure, so ask us to confirm the datasheet and sizing for your application.

GFR200C06LJF2WTK AirTAC Filter Regulator NPT1/8 Technical Specifications

ModelGFR200C06LJF2WTK AirTAC Filter Regulator NPT1/8
SeriesGFR200 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR200C06LJF2WTK AirTAC Filter Regulator NPT1/8

GFR200G-series filter regulator, 200 body — sets the port range.
C0Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR200 · See datasheet · 40 µm
One size upGFR300
Add lubricationGFC200-C0 (two-unit set)

Where the GFR200C06LJF2WTK AirTAC Filter Regulator NPT1/8 Is Used

build

Spray-finishing air prep

Feeding spray guns in a paint or coating booth: the 5 um element strips water and particulate that would spoil a finish, while the regulator holds a steady, reduced atomizing pressure at the gun.

settings_input_component

Low-pressure clamping circuit

Supplying the clamp and hold-down cylinders on a packaging or assembly machine where actuators run at reduced settings - the low-pressure regulator type is intended for exactly this duty, with the gauge giving a direct psi readout.

precision_manufacturing

CNC cell point-of-use drop

A filter regulator at the air drop feeding fixtures and air-assisted tooling on a machining cell, with the reverse/check valve holding the downstream setting while the main supply is vented.

Is the GFR200C06LJF2WTK AirTAC Filter Regulator NPT1/8 the Right Unit?

Size and port step up together: 200 with a 1/8 in port here, then 300, 400 and 600 as demand grows - match the step to your circuit rather than to a single rated number, because AirTAC publishes G-series flow as curves. The real choices on this family are: drain type (differential-pressure as fitted here, automatic, or manual), filter grade (40 um standard, or 5 um like this unit where finer air matters), gauge scale (MPa, psi or bar), thread (PT is the standard; G and NPT are ordered options - this unit is NPT), and bracket (this one comes without, code J). Regulation on this unit is the low-pressure type; its exact set range is not in the published tables, so confirm it with us before ordering if your circuit runs at reduced pressure.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR200C06LJF2WTK AirTAC Filter Regulator NPT1/8 FAQ

AirTAC publishes G-series flow as performance curves rather than a single rated figure, so we do not quote a number here. Tell us your application and we will confirm the flow curve and the datasheet figures for this unit on request.

This is the L (low-pressure) regulator type. The catalogue lists set ranges for the standard types, but the low-pressure variant's range is not in the published tables, so we confirm it on request. Maximum inlet pressure is still 1.0 MPa (145 psi), and the working range is -5 to 70 C, non-freezing.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR200C06LJF2WTK AirTAC Filter Regulator NPT1/8

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR200C06LJF2WTK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.